Toshiba RAS-10PKVPG-NZ Service Manual page 34

Table of Contents

Advertisement

Item
2. Indoor fan
motor control
Fan speed
level
Cool Heat
WF
UH
WE
UH
H
WD
H
M+
WC
M+
WB
M
WA
M
W9
L+
W8
L+
L
W7
L
L-
W6
L-
W5
UL
UL
W4
W3
SUL
W2
SUL
W1
Fan speed
level
Cool Heat
WF
UH
WE
UH
H
WD
H
M+
WC
M+
WB
M
WA
M
W9
L+
W8
L+
L
W7
L
L-
W6
L-
W5
UL
UL
W4
W3
SUL
W2
SUL
W1
Operation flow and applicable data, etc.
(Table 2) Indoor fan air flow rate
Mode
Cooling
PAP
Dry
Fan speed
(rpm)
UH/H
1140
1120
UH
1120
980
M+
H
M+
930
M
/L+
M
780
750
L+
710
L
640
L
620
L-
L-
540
UL
520
UL
SUL/SL-
500
480
SL
SL-
440
(Table 3) Indoor fan air flow rate
Mode
PAP
Dry
Fan speed
(rpm)
UH/H
1160
1160
UH
1150
M+
H
1000
M+
950
M
/L+
M
800
800
L+
730
L
660
L
650
L-
L-
560
UL
540
UL
SUL/SL-
520
SL
500
SL-
440
RAS-13PKVPG-E,-NZ
Heating
Air flow rate
Fan speed
3
(rpm)
(m
/h)
730
1160
700
1140
700
990
950
590
550
840
420
840
400
750
370
660
300
650
290
640
220
560
200
550
190
500
480
170
140
440
RAS-16PKVPG-E,-NZ
Cooling
Air flow rate
Fan speed
3
(rpm)
(m
/h)
750
1160
750
1160
740
1010
620
950
570
860
440
850
440
770
380
680
320
680
310
650
240
580
220
550
200
520
190
500
140
440
- 34 -
FILE NO. SVM-18049
Description
Air flow rate
3
(m
/h)
750
730
610
570
470
470
400
320
310
300
240
230
190
170
140
Heating
Air flow rate
3
(m
/h)
750
750
630
570
490
480
410
330
330
310
250
230
200
190
140

Hide quick links:

Advertisement

Table of Contents
loading