Bush Hog 300 Series Operator's Manual page 55

Rear mounted blade
Hide thumbs Also See for 300 Series:
Table of Contents

Advertisement

Problem
Hydraulic Pump not shutting
off on Closed Center System
Oil leaking at hose
connection
300 Series 09/10
© 2010 Alamo Group Inc.
OPERATION
Possible Cause
Using Open Center Valve
Open Center Conversion Plug
Pumping over Relief Valve
Connection not tight
Did not use sealant
Connection cracked from
over-tightening
Mismatched Connection threads
or types.
Operation Section 4-25
Remedy
Replace Valve or Conversion Plug
and Main Relief
Replace with Closed Center Plug
Replace with No Relief Plug
Tighten connection
Apply a good sealant to connection
Replace cracked connection
Use correct connectors