WARNING
Risk of Fire or Electric Shock
• Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing.
• More than one circuit breaker or disconnect switch may be required to de-energize the equipment before servicing.
• For plastic enclosures, bonding between conduit connections is not automatic and must be provided as part of the installation.
• Installation and/or wiring must be in accordance with National and Local Electrical Code requirements.
• Use #14-#8 AWG wires, rated at least 105°C - COPPER conductors ONLY.
• If the power disconnect point is out of sight, lock it in the OFF position and tag it to prevent unexpected application power.
• Make sure there is no wire insulation under the terminal plate on the time switch connector. Firmly tighten terminal screws.
• For outdoor locations or wet locations (rain-tight), conduit hubs that comply with requirements of the UL514B (standard for fitting conduit and
outlet boxes) are to be used.
• Do not remove insulator that is covering terminals.
• Do NOT exceed maximum current carrying capacity.
• KEEP DOOR CLOSED AT ALL TIMES when not servicing.
NOTICE
• Do NOT touch circuit board components, contact can create a static discharge, which can damage these electronic components.
Description
This document explains the setup and configuration of the Intermatic ET2845
4-Circuit Electronic Astronomic 365/7-Day Time Switch. The ET2845 time switch
automatically switches loads according to the weekly schedule that is entered.
The time switch can support up to 48 fixed ON and 48 fixed OFF events (96 total)
and up to 8 Astro events. Each fixed event can be applied to any combination of
circuits and days.
The time switch features an LCD and panel-mounted control buttons to set,
review, and monitor the time switch functions, including setting date and time,
schedule creation, enabling or disabling Daylight Saving Time (DST) and
configuring DST switchover dates.
Follow these instructions to complete the installation and programming of the
ET2845 time switch.
Federal Communications Commission (FCC) Notice for ET2000 Series Time Switches
This device complies with part 15 of the FCC rules. Operation of this device is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any interference, including interference that may cause
undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses and radiates radio frequency energy and, if
not installed and used in ac-cordance with instructions, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference that requires the user to correct at his or her own expense.
Astronomic 365/7-Day Time Switch
Electronic 4-Circuit
With 100-Hour Backup
Shown in indoor/outdoor
lockable metal enclosure

Advertisement

loading

Summary of Contents for Intermatic ET2845C

  • Page 1 • Do NOT touch circuit board components, contact can create a static discharge, which can damage these electronic components. Description This document explains the setup and configuration of the Intermatic ET2845 4-Circuit Electronic Astronomic 365/7-Day Time Switch. The ET2845 time switch automatically switches loads according to the weekly schedule that is entered.
  • Page 2: Installation

    Installation Latch location Tilt top forward Wiring Diagrams Follow these instructions to install the time switch. TIMER CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 TIMER POWER POWER Open the time switch enclosure door. Remove and retain the screw that secures the plastic insulator. Lift the left side of the plastic insulator and pivot away to expose the terminal strip.
  • Page 3 Initial Setup Enable/Disable Daylight Saving Time and Setting Daylight Saving Time Rule Configure the time switch to automatically adjust for Daylight Saving Time (DST). If DST does not apply to your region, disable the The following sections provide instructions for the initial setup of the time switch. option as directed in this procedure.
  • Page 4 The LAT (latitude) entry screen appears showing the value of the selected geographical location. Programming Events Users can configure Astro events, fixed timed events, or a combination of Astro and fixed timed events. Then Perform the applicable instructions below. LAT accuracy does not require Press ENTER/NEXT twice to scroll past the latitude and longitude screens to the •...
  • Page 5 Setting Fixed Timed Events Setting Holidays Access the Fixed ON/OFF screen to set fixed switching times. Odd-numbered events are for ON switching and even-numbered There are 50 Holiday blocks that can be programmed along with a single schedule for each block. For each block there will be a events are for OFF switching.
  • Page 6 Enclosures: Rainproof Type 3R indoor/outdoor lockable metal enclosure (ET2845CR), Type 1 indoor lockable metal enclosure (ET2845C), Rainproof Type 3R indoor/outdoor lockable plastic enclosure (ET2845CP) SCHEdL.xx is displayed where xx is the first data file number found on the USB memory stick.
  • Page 7: Limited Two-Year Warranty

    LIMITED TWO-YEAR WARRANTY If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is extended to the original household purchaser only and is not transferable.