Unit Model Number Description - Trane IC-IH 039 Installation Operation & Maintenance

Table of Contents

Advertisement

Unit Model Number Description

Digit 1 - Manufacturing location
E = Epinal France
Digit 2 - Unit Model
I = Airfinity
Digit 3 - Unit type
C = Cooling only
H = Reversible Heat pump
Digit 4-5-6 Unit Nominal Capacity
021 = 20 kW Heat Pump only
031 = 30 kW Heat Pump only
038 = 38 kW
039 = 39 kW
040 = 40 kW
041 = 40 kW Heat Pump only
048 = 48 kW Cooling only
049 = 49 kW
050 = 50 kW
051 = 50 kW Heat Pump only
058 = 58 kW Cooling only
059 = 59 kW
060 = 60 kW
061 = 60 kW Heat Pump only
063 = 63 kW Cooling only
064 = 64 kW
065 = 65 kW
071 = 64 kW Heat Pump only
074 = 74 kW
075 = 75 kW
084 = 84 kW
085 = 85 kW
100 = 100 kW
110 = 110 kW
130 = 130 kW
Digit 7 - Efficiency level
A = Adaptive Frequency Drive
S = Standard efficiency
Digit 8 - Refrigerant
A = R410A Factory full refrigerant charge
8 = R410A Factory refrigerant pre charge
Digit 9 - Unit voltage
E = 400 V - 3 Ph - 50 Hz
Digit 10 - Design Sequence
Digit 11 - Design Sequence
Digit 12 - Auxiliary Heat
X = Without
W = Hot water coil
E = Electric heater
M = Modulating burner
Digit 13 - Gas type
X = Without
1 = Propane gas
2 = Natural gas (G20)
3 = Natural gas (G25)
6
Digit 14 - Airflow configuration
D = Down Supply & Down Return
H = Horizontal Supply & Horizontal Return
I = Down Supply & Horizontal Return
J = Horizontal Supply & Down Return
Digit 15 - Available static pressure
1 = Standard External Static Pressure
2 = High External Static Pressure
Digit 16 - Operating map (cooling mode)
A = Standard ambient
L = Low ambient
Digit 17 - Free cooling (Economizer)
A = Temperature control
B = Enthalpy control
X = Without (full recirculation)
Digit 18 - Heat Recovery Module
X = Without
R = Configured for Rotary Wheel
B = Configured for Rotary wheel high airflow
T = Energy Recovery Circuit fan AC
U = Energy Recovery Circuit fan EC
Digit 19 - Dehumidification
X = Without
A = Dehumidification control
Digit 20 - Outdoor coil treatment
B = Without
E = With
Digit 21 - Indoor coil treatment
1 = Without
2 = With
Digit 22 - Filtration
A = G4 (50 mm) filters
B = G4 (50 mm) + F7 (100 mm) filters
C = G4 (50 mm) + F9 (100 mm) filters
D = F5 (50 mm) + F7 (100 mm) filters
Digit 23 - Temperature Zone sensor
X = Without
A = Duct-mounted zone sensor
B = Wall mounted zone sensor
Digit 24 - Room User Interface
X = Without
A = Wall-mounted interface THP05
B = Conventional thermostat
Digit 25 - C0 2 sensor
X = Without
1 = CO 2 sensor duct-mounted
2 = CO 2 sensor wall-mounted
Digit 26 - Smoke detector
X = Without
1 = With
RT-SVX056D-GB