10. Reconnect coupling. When sanitizing cycle ends,
machine will start producing ice. Press power switch ON.
Ice pushes Sani-Sponges through tube (Fig. 10).
11. Place a sanitary (2 gallon or larger) container in bin or
dispenser to collect Sani-Sponges and ice for 10 minutes.
Collect 5.5 lbs (3kg) of ice from unit. Discard ice and
Sani-Sponges (Fig. 11).
Horizon HCD700R/N, HMD700R/N Ice Machines
Fig. 10
Fig. 11