Troubleshooting Information - Universal Security Instruments MIC1509S Manual

Table of Contents

Advertisement

C O N D I T I O N
New - Out of package.
AC power is present.
DC power is present.
Alarm is powered
by battery backup.
AC power not present.
The Test button has been
pressed. The test sequence
lasts for approx 10 seconds
One or more alarms not
responding to
interconnected alarm.
Originating Smoke Alarm
The Test button has been
pressed. The test sequence
lasts for approx 10 seconds.
One or more alarms not
responding to
interconnected alarm.
Originating Smoke Alarm
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY, UL 217 and UL 2034
ALARM AUDIBLE & VISUAL SIGNALS
HORN
PWR
GREEN
LED
Off
Off
Silent
Stays On
Silent
Off
3 Beeps,
Stays On
6 second
pause,
4 beeps.
Horn does
Stays On
not sound
when other
alarms are
active or when
test button is
pressed on
interconnected
alarm
3 Beeps, 2
Stays On
second pause,
repeat
3 Beeps,
Stays On
6 second
pause, 4
beeps.
Horn does
Stays On
not sound
when other
alarms are
active or when
test button is
pressed on
interconnected
alarm
3 Beeps, 2
Stays On
second pause,
repeat
SMK RED
CO RED
LED
LED
Off
Off
Blinks On
Off
approx. every
2 minutes.
Blinks On
Off
approx. every
2 minutes.
Blinks On in
Blinks On in
sync with 3
sync with 4
beeps.
beeps.
Blinks on
Off
approx. every
2 minutes
Blinks on in
Off
sync with 3
beeps
Blinks On in
Blinks On in
sync with 3
sync with 4
beeps.
beeps.
Blinks on
Off
approx. every
2 minutes
Blinks on in
Off
sync with 3
beeps
Page 16
RECOMMENDATION
To activate the alarm remove the pull tab. The
alarm will sound one long beep to let you know
it is powered up.
Alarm is operating properly.
Check the breaker or fuse box for power. If
the breaker or fuse box looks normal, call a
licensed electrician for assistance.
Test the alarm following installation and weekly
thereafter. The built-in test switch accurately
tests the alarm operation as required by ANSI/
UL217 and UL2034 Standards for Safety. If,
at any time, the alarm does not perform as de-
scribed during the test, replace it immediately.
Press and hold the smoke alarm Test button
for at least 5 seconds. If still no alarm, turn off
AC Power at the circuit breaker or fuse box
and disconnect the alarm from the mounting
bracket and make sure the connector plug
is securely attached on alarms that did
not sound. If still no alarm, have licensed
electrician make sure the yellow wire is not
mistakenly or accidentally connected to the
white (neutral) wire. NOTE: In an intercon-
nected system containing a CO alarm, the
CO alarm will not respond to the smoke alarm
signal and the smoke alarm will not respond to
the CO alarm signal.
If hazard is identified please take all precau-
tions if an alarm sounds by calling an Emer-
gency Service and getting out of the home.
Test the alarm following installation and weekly
thereafter. The built-in test switch accurately
tests the alarm operation as required by ANSI/
UL217 and UL2034 Standards for Safety. If,
at any time, the alarm does not perform as de-
scribed during the test, replace it immediately.
Press and hold the smoke alarm Test button
for at least 5 seconds. If still no alarm, turn off
AC Power at the circuit breaker or fuse box
and disconnect the alarm from the mounting
bracket and make sure the connector plug
is securely attached on alarms that did
not sound. If still no alarm, have licensed
electrician make sure the yellow wire is not
mistakenly or accidentally connected to the
white (neutral) wire. NOTE: In an intercon-
nected system containing a CO alarm, the
CO alarm will not respond to the smoke alarm
signal and the smoke alarm will not respond to
the CO alarm signal.
If hazard is identified please take all precau-
tions if an alarm sounds by calling an Emer-
gency Service and getting out of the home.