Standing Pilot Lighting Instructions - Empire Comfort Systems DVP36PP32EN-4 Installation Instructions Manual

Direct-vent zero clearance gas fireplace heater
Table of Contents

Advertisement

STANDING PILOT LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When
lighting the pilot, follow these instructions exactly.
B. Before lighting smell all around the appliance area for gas. Be
sure to smell next to the floor because some gas is heavier
than air and will settle on the floor.
What To Do If You Smell Gas
Do not try to light any appliance.
Do not touch any electrical switch;
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
1. Stop! Read the safety information above.
2. Set REMOTE/OFF/ON switch to OFF.
3. Turn off all electric power to the appliance (if applicable).
4. Lower bottom louver assembly.
5. Push in gas control knob slightly and turn clockwise
to "OFF."
GAS CONTROL KNOB SHOWN
IN "OFF" POSITION
Note: Knob cannot be turned from "PILOT" to "OFF" unless
knob is pushed in slightly. Do not force.
6. Wait ten (10) minutes to clear out any gas. Then smell for gas,
including near the floor. If you then smell gas, STOP! Follow
"B" in the safety information above. If you do not smell gas, go
to the next step.
7. Find pilot - Follow metal tube from gas control. The pilot is
behind the burner on the right side.
8. Turn gas control knob counterclockwise
to "PILOT."
1.
Set REMOTE/OFF/ON switch to OFF.
2.
Turn off all electric power to the appliance if service is to be
performed (if applicable).
3.
Lower bottom louver assembly.
Page 50
LIGHTING INSTRUCTIONS
REMOTE
REMOTE
OFF
OFF
ON
ON
THERMOCOUPLE
THERMOCOUPLE
ELECTRODE
ELECTRODE
THERMOPILE
THERMOPILE
PILOT
PILOT
TO TURN OFF GAS TO FIREPLACE
WARNING
If you cannot reach your gas supplier, call the fire depart-
ment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
don't try to repair it; call a qualified service technician. Force
or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
9. Push in control knob all the way and hold in. Repeatedly push
the piezo ignitor button until the pilot is lit. Continue to hold the
control knob in the for about one (1) minute after the pilot is lit.
Release knob, and it will pop back up. Pilot should remain lit.
If it goes out, repeat steps 5 through 9.
If the control knob does not pop up when released,
STOP and IMMEDIATELY call a qualified service technician
or gas supplier.
If the pilot will not stay lit after several tries, turn the
gas control knob to "OFF" and call your service technician or
gas supplier.
10. Turn gas control knob counterclockwise
11. Close bottom louver assembly.
12. Turn on all electric power to the appliance (if applicable).
13. Set REMOTE/OFF/ON switch to desired setting.
4.
Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.
5.
Close bottom louver assembly.
to "ON."