Water Temperature Sensor - Central Boiler CLASSIC Owner's Manual

Table of Contents

Advertisement

Fig. 41
5. Depress the tabs on the side of the controller mounting
strap; then slide the strap off the controller. Remove
the controller from the control panel.
6. Place the new gasket onto the controller. Slide the new
controller into position (making sure it is positioned
upward) in the control panel; then secure with the
mounting strap.
7. Slide each of the labeled wires into their proper
positions on the controller; then tighten each of the
screws securely.
8. Place the inner door panel into position on the door
and secure with the screws.
9. Close and secure the door. Connect power to the
furnace.

WATER TEMPERATURE SENSOR

1. Remove all wood and live coals from the firebox.
CAUTION
Remove all wood and live coals from the outdoor
wood furnace. Do not perform this procedure with
any live coals in the furnace.
2. Disconnect the electrical power at the main power source
to the outdoor wood furnace; then open the control
panel door. Remove the screws securing the access
box panel; then remove the panel.
WARNING
Do not attempt service inside the electrical control
panel without first disconnecting the electrical
power at the main power source.
Section 5 - Owner Serviceable Items
Fig. 42
Water Temperature Well
3. Remove (by pulling) the sensor wire from the well.
4. Firmly press the sensor wire into the well.
5. Place the access box panel into position and secure
with the screws.
6. Close and secure the door. Connect power to the
furnace.
Sensor Wire
Temperature Controller
33
Section
5