3.12 Install DE back into frame <= SSR Task
CAUTION:
DANGER:
severe injury or death. (L004)
STEP 54
Attention: Ensure that all the cables of the frame are clear so that the Lift Tool table will not catch on cables
as it is moved up and down across the face of the frame. Also ensure that the UEPO Panel is still out of the way.
STEP 55
Using Battery powered drill shipped with the Lift Tool, 5/16 inch socket , ¼ inch drive adapter P/N 39F8449, raise
the Lift Tool table until the DE is lined up with the frame location that it was removed from.
STEP 56
Align the DE channels with the DE rail rollers and applying force to the cable tray, slide the DE back into the
frame carefully. Be careful not to damage any cables.
ATTENTION: Do not push on any FRUs. Apply force only to the cable tray.
STEP 57
Install the two Rear Rail Block Captive Allen head screws (see Figure 27).
STEP 58
Attach the water hoses by pushing the quick connects onto the DE water connectors.
STEP 59
Reconnect the rear SAS cables. Using the Location Codes labels, install the cables to the correct Port Card
connectors. Each cable end should have two labels. The label closest to the connector (between the SN label and
the connector) tells you the location to plug that end. The label on the other side of the SN label tells you where
the other end of the cable is plugged. The convention for the label is like the location code of the port: <frame
location> <card location><connector location>.
If velcro ties were removed, reinstall them.
When complete, all the Port Card connectors should be populated; there should be no open connectors.
STEP 60
Close the rear door of the frame.
STEP 61
Lower the Lift Tool, detach it from the frame, and store it.
a.
Retract the table extensions and stop plate extended in STEP 36 and STEP 37.
b.
Detach the Lift Tool brackets that were installed in STEP 32. Be sure to completely disengage brackets
from frame before attempting to move Lift Tool.
c.
Using the battery powered drill lower the Lift Tool table to its lowest most stable position. Attention:
Watch to ensure cables are clear during this operation!
d. Store the winch with Lift Tool for future use.
Power775 Disk Enclosure Rail Service Procedure
Do not remove or install this unit without using the provided lift tool. (C017)
Hazardous voltage present. Voltages present constitute a shock hazard, which can cause