Indicator Message (Error Message) - NEC UM383WL User Manual

Table of Contents

Advertisement

Indicator Message (Error message)

POWER
STATUS
Blink
Orange
(Light)
Blue (Blink*
)
Off
4
Blue
Off
(Light)
Red
Off
(Blink*
)
4
Red
Green
(Blink*
)
(Light)
4
Red
Status varies
(Light)
*1 Repetition to light on for 1.5 seconds / off for 1.5 seconds
*2 Repetition to light on for 1.5 seconds / off for 7.5 seconds
*3 Repetition to light on for 2.5 seconds / off for 0.5 seconds
*4 Repetition to light on for 0.5 seconds / off for 0.5 seconds
When the thermal protector is activated:
When inside temperature of the projector becomes too high or low, the POWER indicator start to red blink in a
short cycle. After this happened, the thermal protector will activate and the projector may be turned off.
In this case, please take the below measures:
- Pull out the power plug from the wall inlet.
- Place the projector in cool place if it has been placed in high ambient temperature.
- Clean the exhaust vent if dust has accumulated on.
- Leave the projector for about one hour until inside temperature gets lower.
LIGHT
A button has been pressed while the
KEY LOCK is activated.
Status varies
ID numbers for the projector and the
remote control do not match.
Preparing to relight light after lighting
has failed.
Green (Blink*
)
4
Temperature problem (In the Forced
ECO)
Orange
(Light)
Temperature problem
Off
Light does not light.
Red
(Light)
Error requiring service support
Status varies
Projector status
97
8. Appendix
Procedure
The projector's keys are locked. The
setting must be canceled to operate the
projector. (
page 69)
Check the control IDs (
page 70)
Wait a while.
Ambient temperature is high. Lower the
room temperature.
Ambient temperature is out of the opera-
tion temperature. Check if any obstruction
stays near the exhaust vent.
Wait at least 1 minute, then turn on the
power back on. if the light still does
not light, contact your dealer or service
personnel.
Contact your dealer or service personnel.
Make sure to check and inform indicator
status for asking to repair.