Connecting
8.10 Digital inputs/outputs
Pin
4
5
6
7
8
9
10
11
12
13
14
Signal type: B = Bidirectional; I = Input; GND = Reference potential (ground)
In the "Default setting" column, the signals for which the associated SINAMICS parameters are set when
configuring a SINAMICS device are marked with "x".
Table 8-19
Pin
1
2
3
80
Signal
Signal
Meaning
name
type
DI3
I
Digital input 3
Selection safe standstill group 2
SH/SBC - Group 2 SINAMICS Safety Integrated (SH =
p9601 release)
DI16
I
Digital input 16
Freely available
DI17
I
Digital input 17
Freely available
G1
GND
Ground for DI0 - DI3, DI16, DI17 (isolated with respect
to M)
M
GND
Ground for DI8 - DI11
DI/DO8
B
Digital input/output 8 (rapid input)
Status safe standstill group 1
SH/SBC - Group 1
SINAMICS Safety Integrated
DI/DO9
B
Digital input/output 9 (rapid input)
Status safe standstill group 2
SH/SBC - Group 2
SINAMICS Safety Integrated
M
GND
Ground for DI8 - DI11
DI/DO10
B
Digital input/output 10 (rapid input)
Input, external zero mark - BERO 1
DI/DO11
B
Digital input/output 11
(rapid input)
M
GND
Ground for DI8 - DI11
X132 digital inputs/outputs
Signal
Signal
Meaning
name
type
DI4
I
Digital input 4
Freely available
DI5
I
Digital input 5
Freely available
DI6
I
Digital input 6
Freely available
Input, probe 1 - central
measuring (check that
MD13210 = 0)
Input, probe 1 - distributed
measurement (check that
MD13210 = 1)
Equipment Manual, 10/2021, A5E51087503B AA
Default set‐
ting
---
---
---
---
---
---
---
x
---
Default set‐
ting
---
---
---
NCU 1740