Additional Operation Features

Review Set Temperature
1. Press and hold or button. The current
set point temperature will be displayed in
place of the current room temperature, and
the indicator SET will be displayed.
2. The display will return to normal operating
mode when the or button is released.
Continuing to hold the or button for 3
seconds or longer will allow the user to temporarily override the current
programmed set point (See Temporary Program Override).
Temporary Program Override
1. Press and hold or button for 1 second.
The entire display will flash once and the
SET indicator will be displayed. Release
the or button and press the or
button again as desired to adjust the set
temperature.
2. The display will return to normal operating
mode after 15 seconds or you can press RETURN button.
3. The program indicator (MORN, DAY, EVE or NIGHT) will be flashing in the display
indicating that a Temporary Program Override is in effect. The Temporary
Program Override will reset when the next set point time occurs or after four
hours–whichever comes first.
Extended Hold (Vacation) Mode
1. Press the HOLD button to bypass the
program schedule. The current set point
temperature will be held either
permanently or for 24 hours depending
on the setting selection made for Setting
the Extended Hold Time (see page 5).
2. Press the HOLD button again to return the
thermostat to normal program operation.
3. The hold period lasts until the hold is released as in step number 2 above, or is
limited to 24 hours if the default extended hold time was changed (see Setting
the Extended Hold Time, page 5).
Filter Check Monitor (see section 4)
The Filter Check Monitor displays a reminder
for required filter replacement or cleaning by
flashing the FILT segment in the display. See
instructions on your filter or heating/cooling
unit for recommendations for interval setting.
When the selected interval has been reached,
and required cleaning or replacement has
been performed, press the RETURN button in any normal mode to reset the timer
and turn off the warning.
10
5
Additional Operation Features
Locking the Keypad
To prevent accidental or undesired
adjustment of the thermostat, the Keypad
Lockout feature disables the operation of
the keypad except for the backlight key. In
order to lock the keypad, press and hold
both the and buttons together at the
same time for 5 seconds. The LOCK
segment in the display will flash once per second, and then appear continuously
in the display. The keypad is now locked.
To unlock the keypad, press and hold the and buttons together at the same
time for 1 second. The LOCK segment will disappear and the keypad will
become unlocked.
Adaptive Recovery Mode (ARM™) (see section 4)
In order to maximize comfort and energy efficiency, this thermostat is equipped
with an Adaptive Recovery Mode (ARM™). This feature minimizes the amount of
time required by heating or cooling system to reach the new set point, after a
setback period is completed, and assures your desired temperature is achieved
at your set program times.
This feature activates when recovering room temperature from setback programs
to comfort programs, so it will only take place when the current (heating)
program set point temperature is lower than the upcoming program set point
temperature, or the current (cooling) program set point temperature is higher
than the upcoming program set point temperature.
During ARM™, room temperature is recovered gradually by turning on the
heating or cooling before the end of the setback period. The set point temperature
is changed to that of the upcoming comfort program temperature. The start time
of recovery is based on the difference between the current room temperature and
the upcoming comfort program set point temperature. The recovery to the
upcoming set point starts 10 to 15 minutes before the upcoming set point time
for each degree of temperature change required, up to a maximum of 2 hours in
the HEAT mode, 3 hours in the COOL mode.
ARM™ does not operate when the unit is in HOLD mode, or if the program is
temporarily overridden.
Recirculating Fan Mode (see section 4)
The Recirculating Fan Mode provides more even temperature distribution and
improves indoor air quality by circulating air through the furnace filtration system
more often. The Recirculating Fan Mode can be selected by moving the fan
switch to the recirculate position(
within the fan off cycle set in section 4, the fan will run for 12 minutes. The
highest setting, 120 minutes (factory default), will run the fan least often–9%
minimum run time. The lowest setting, 40 minutes, will run the fan most
often–23% minimum run time. During any call for heating or cooling, the fan
operates in the AUTO mode. The Recirculating Fan feature is available in the
HEAT, OFF, or COOL mode.