Old Terminal from Existing Thermostat | New Terminal for New Thermostat | Terminal Description |
R, V-VR or VR-R | R | 24 Volt AC |
Y, Y1 or M | Y1 | Stage 1 Cooling or Heating |
Y2 | Y2 | Stage 2 Cooling |
W1, W2 or W-U | W2 | Stage 2 Heating |
E | E | Emergency Heating |
G or F | G | Fan Control |
O or R | O | Reversing Valve (Cooling) |
B | B | Reversing Valve (Heating) |
L or X | L | System Status LED |
C, X or B | C | 24 Volt AC, Transformer Common |
NOTE: This thermostat is for use on low voltage 24 Volt AC multi-stage heat pump systems with up to two stages of heating and two stages of cooling and requires a transformer common wire for proper installation. This thermostat is not for use on single stage heating or cooling systems.
NOTE: If you are installing this thermostat in a new installation be sure to locate the thermostat 4 to 5 feet above the floor in accordance with applicable building codes. Make sure to install the thermostat in a location that provides good airflow characteristics and avoid areas behind doors, near corners, air vents, direct sunlight or near any heat generating device. Installation in any of these areas could impact thermostat performance.
Read BEFORE Testing
NOTE: Test your thermostat prior to programming any user settings. Pressing the RESET button will erase any user entries previously programmed. This will erase all user settings and return them to their default values.
Function | Status After Reset |
Operation Mode | Normal Operating Mode |
Room Temperature | 70˚ F (21.0˚ C), to be renewed within 5 seconds |
Set point Temperature | According to system switch: 62˚ F (17.0˚ C) for Heat or Off 85˚ F (29.0˚ C) for Cool |
Temperature Scale | ˚F or ˚C dependent on switch setting |
Low Battery Warning | Off, to be renewed within 5 seconds |
First Stage Differential | .5˚ F (0.25˚ C) |
Second Stage Differential | 2.0˚ F (1.0˚ C) |
Short Cycle Protection Timer | Reset |
Output Relays | Off |
Residual Cooling Fan Delay | 60 Seconds |
Recirculating Fan Timer | Reset with 120 Min. Off Cycle |
Keypad Lock | Unlocked |
The default settings for the first and second stage differentials and residual cooling fan delay settings are compatible with most systems and applications. This is normally set at time of installation and usually does not require any modification under normal operating conditions. If you feel that the first or second stage of your system is turning on too often, or you wish to change the fan delay settings, simply follow the instructions below.
NOTE: The first and second stage differential settings are the same for both the heating and cooling systems.
Setting First Stage Differential
The default setting is.5˚ F (0.25˚ C). The room temperature must change.5˚ F (0.25˚ C) from the set point temperature before the thermostat will initiate the system in heating or cooling.
NOTE: If you do not desire to change the second stage differential setting, you can press the and buttons at the same time twice to proceed to the Residual Cooling Fan setting–see step 4.3.
Setting Second Stage Differential
The default setting is 2˚ F (1.0˚ C). This means that the room temperature must change 2˚ F (1.0˚ C) in addition to the first stage differential setting before the thermostat will initiate the second stage of the system in heating or cooling.
The default setting is 60 seconds. During the COOL mode of normal operation the fan will stay on for 60 seconds after the cooling system has satisfied the set point temperature and has turned off the compressor. This allows the system to provide higher efficiency during cooling operation.
The default is 120 minutes.
NOTE: To erase all user program settings, gently press the RESET button using a paper clip or a small pencil tip. This will return all thermostat settings to their default values, and erase all user program settings entered by the user.
The Recirculating Fan Mode provides more even temperature distribution and improves indoor air quality by circulation air through the furnace filtration system more often. The Recirculating Fan Mode can be selected by moving the fan switch to the recirculate position . If no call for heating or cooling occurs within the fan off cycle set in section 4.4, the fan will run for 12 minutes. The highest setting, 120 minutes (factory default), will run the fan least often–10% minimum run time. The lowest setting, 40 minutes, will run the fan most often–30% minimum run time. During any call for heating or cooling, fan control operates in the AUTO mode. The Recirculating Fan feature is available in the HEAT, OFF, or COOL mode.
To prevent accidental or undesired adjustment of the thermostat set point, the Keypad Lockout feature disables the operation of the temperature setting keys, but not the backlight key. In order to enable the keypad lock, press and hold either the or button together with the backlight button for 5 seconds. The LOCK icon in the display will flash once per second, then appear continuously in the display. The keypad is now locked.
To unlock the keypad, press and hold either the or button together with the backlight key for 1 second. The LOCK icon will disappear from the display, and the keypad is now unlocked.
The Model 3200 is equipped with an auxiliary heat option switch which is set at installation for either an electric or fossil fuel (gas, oil or propane) auxiliary heat source. For heat pump units with an electric auxiliary stage, both the first and second stages of heating will run when a call for second stage heat is made. For heat pump units with a fossil fuel auxiliary stage, the first stage will be locked out one minute after a second stage heat call, and the second stage alone will be used to recover to the set point, improving the efficiency of your heat pump unit.
This thermostat includes an automatic compressor protection feature to avoid potential damage to the heat pump system from short cycling. This thermostat automatically provides a 5-minute delay after turning off the heating or cooling heat pump output to protect the compressor.
NOTE: The installer can reset the thermostat and bypass the compressor protection features by pressing the RESET button. This will erase all user program settings and should only be used during installation for testing purposes or to reset a thermostat to regain normal operation. This will return all thermostat settings to their default values.
The user will have to re-program all of the erased settings.
The Reset feature allows the user to completely reset the thermostat. To erase all entered program settings, gently press the RESET button using a paper clip or a small pencil tip. This will return all thermostat settings to their default values and register all new manual switch settings.
The three multi-colored LED status indicators located on the front of your thermostat above the display will notify you of key system information.
AUX (Green): This will turn on when the auxiliary second stage of heating is active. The auxiliary stage of heating is usually the least economical stage of heat.
CHECK (Red): Indicator will activate when a malfunction occurs in the heat pump system.
When this light is active, call a professional service technician to verify system performance and switch the system to Emergency Heat Mode if required to maintain room temperature.
EMER (Red): This indicator will light when you select Emergency Heat Mode of operation using the system selector switch. When you select Emergency Heat Mode, the heat pump stage of heat is turned off and the emergency (auxiliary) stage of heating is used to maintain the set point temperature.
SYMPTOM | POTENTIAL SOLUTION |
Thermostat does not turn on heating or cooling system | Check to see if OFF is shown in display. This indicates that the system is turned off at the thermostat. Move the system selector switch to the HEAT or COOL position. After the compressor short cycle protection 5-minute period expires, the system should start within a minute. Compressor protection features may be in effect due to compressor short cycle conditions. See Compressor Protection section for full explanation of this feature. Heat Pump may be malfunctioning. Review the CHECK status indicator light to see if it is lit. If the CHECK status indicator light is lit, call a professional service technician to confirm heat pump operation and provide necessary service. If heating is required you can slide the system switch to EMER setting which will start the Emergency Heat source to provide heating until the heat pump can be serviced. |
Thermostat turns on heating instead of cooling or cooling instead of heating. | Check thermostat wiring to make sure that the heating and cooling stages are connected to the correct terminals on the wiring terminal block. See Installation and Wiring Diagram sections of this manual. |
Thermostat turns heating or cooling system on too often or not often enough. | Increase or decrease first stage temperature differential setting as appropriate to provide the desired performance level. See Setting Temperature Differential and Residual Cooling Fan Feature section of this manual. |
Thermostat turns on second (auxiliary) stage of heating or cooling too quickly or not quickly enough. | Increase or decrease second (auxiliary) stage temperature differential setting as appropriate to provide the desired performance level. See Setting Temperature Differential and Residual Cooling Fan Feature section of this manual. |
OFF is shown in thermostat display and heating or cooling system will not start. | This indicates that the system is turned off at the thermostat. Move the system selector switch to the HEAT or COOL position. After the compressor short cycle protection 5-minute period expires the system should start within several seconds. |
Thermostat display is blank | It is possible that AC power is not present at the thermostat. Check fuse, circuit breaker and thermostat wiring as appropriate to verify AC power is available. If AC Power is present, call a professional service technician immediately to verify thermostat and system performance. |
HI is shown in the thermostat display where the room temperature is normally displayed. | The temperature sensed by the thermostat is higher than the 90˚ F (32˚ C) upper limit of the thermostats display range. The display will return to normal after the sensed temperature lowers within the 45˚ to 90˚ F (7˚ to 32˚ C) display range. Turn on the cooling system or use other methods to lower the temperature accordingly. This condition could occur from the system being turned off during an exceptionally warm period or upon installation when the thermostat has been stored for a long period of time in a warm vehicle or location prior to being installed. The thermostat is equipped with a mechanical high temperature safety switch that will turn off the thermostat should the temperature exceed 99˚ F (37˚ C). |
LO is shown in the thermostat display where the room temperature is normally displayed. | The temperature sensed by the thermostat is lower than the 45˚ F (7˚ C) lower limit of the thermostats display range. The display will return to normal after the sensed temperature rises within the 45˚ to 90˚ F (7˚ to 32˚ C) display range. If the temperature in the controlled space seems to be normal, wait for the thermostat to acclimate to the correct room temperature. If the room seems to be colder than usual, turn on the heating system to raise the temperature as needed for comfort within the room. This condition could occur from the system being turned off during a cold weather period or upon installation when the thermostat has been stored for a long period of time in a cold vehicle or location prior to being installed. The thermostat should be allowed to warm up prior to installation to allow proper heating control once installed. |
Thermostat will not allow me to program a set point temperature higher than 90˚ F (32˚ C). | This is above the normal thermostat temperature setting range of 45˚ to 90˚ F (7˚ to 32˚ C). |
Thermostat will not allow me to program a set point temperature lower than 45˚ F (7˚ C). | This is below the normal thermostat temperature setting range of 45˚ to 90˚ F (7˚ to 32˚ C). |
Fan continues to run all the time whether the system is on or off. | Check that the fan control switch is in the AUTO position. This will allow the fan to run only when the heating or cooling system is turned on and running. Check thermostat wiring to make sure that the fan control wiring is connected to the correct terminals on the wiring terminal block. See Installation and Wiring Diagram sections of this manual. |
Fan continues to run in cooling mode when the system has turned off. | The Residual Cooling Fan Control Feature can allow up to a 90 second fan delay after cooling system shutdown for energy efficiency gains. The default setting is 60 seconds. This can be changed to disable this feature or shorten the time period if desired. See Setting Residual Cooling Fan Feature section of this manual. |
The room is too warm or too cold | See Review Set Temperature section of this manual to verify the current set point and make any modifications that are necessary. |
Thermostat will not allow me to change the set point. | Keypad is locked. press either the or key along with the backlight key to unlock. |
Fan runs intermittently or when system is off | Fan switch is in the Recirculate Mode . |
Wiring Diagram for 2 Stage Heat, 2 Stage Cool Systems
NOTES:
Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S. Only)
630-844-1968 (Outside the U.S.)
© 2005 Braeburn Systems LLC • Patents Pending
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Braeburn Premier 3200 - Non-Programmable Digital Thermostat Manual
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the 3200 that isn't answered in the manual? Leave your question here.