Si241319
2. Procedure to Remove Propeller Fan and Fan
Motor
Procedure
Step
Removing top panel and
front panel according to
the "Procedure to
Remove Outside Panels".
1. Removing propeller fan
1
Dismount 4 screws
fixing discharge grille
and disengage 4 hooks
located at upper and
lower sides of the grille
to remove the grille.
Remove fan stopper
2
and washer faced nut
fixing propeller fan.
2. Removing the fan motor
Disconnect the
1
connector for fan motor
from the el. compo.
box.
Pull out the fastening
2
terminal from Capacitor
(C1R).
3
The lead wires are
clamped at 3 locations.
4
Fan motor can be
removed by removing 4
fixing bolts.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Propeller fan
Hook
Fan motor
Screws

Procedure to Remove Propeller Fan and Fan Motor

Washer faced
Do not pull the lead wire but
Capacitor
hold the connector and press
(C1R)
the hook section when
disconnect the connector.
Lead wire
Precautions for installing
motor
Be sure to fix the motor lead
wire with clamps, or the lead
wire could be caught with fan
resulting damage of parts.
Clamps
Points
Propeller fan
3

Advertisement