Replacing The Thermo Fuse; Models Only); Testing The Thermofuse For Continuity (New Generation Models Only) - Dometic DM2652 Service Manual

Table of Contents

Advertisement

Americana and New Generation Refrigerators

8.38 Replacing the Thermo Fuse

(Americana Models Only)
q
37 Removing the Thermo Fuse
Thermo Fuse
q
1. Disconnect the unit from all power sources (120 VAC
and 12 VDC).
2. Disconnect the wires to the thermo fuse.
3. Remove the screws/rivets securing the thermo fuse
to the flue stack.
4. Remove the defective thermo fuse.
5. Perform these steps in reverse to complete the
replacement.
EN
w
Flue Stack
w
8.39 Testing the Thermofuse for
Continuity (New Generation Models
Only)
38 Testing the Thermofuse Blades
Thermofuse
q
1. Perform the steps in "Replacing the Thermofuse
(New Generation Models Only)" on page 48 to
disconnect the wiring from the thermofuse.
2. Attach the one lead of the multi-meter to each blade
of the thermofuse.
The reading should show continuity.
3. If the reading shows no continuity, reset the
thermofuse by pressing the center button.
4. Retest for continuity.
If the reading shows no continuity after the reset, it
indicates a blown fuse.
I
Consult the operating manual for the multi-meter
for specific device function.
Service Procedures
q
w
Blades
w
47