Battery Location
Premium AA alkaline batteries
are required when C-wire is
not available. When C-wire is
available, the batteries provide
a back-up source of power (this
will maintain the clock in the
event of a power outage).
1.) W2/E Jumper Wire
This thermostat electrically connect the W2 and E terminals so that you do not need to do
this with a jumper wire. If your system has separate W2 and E wires, clip the W2/E jumper
located on the back of the thermostat. This will isolate both terminals so they can be used
independently.
2.) O/B Terminal Switch
The O/B switch on this thermostat is factory set to the O position. This will accommodate
the majority of heat pump applications, which require the changeover relay to be
energized in Cool. If the heat pump being installed requires a B terminal to energize the
changeover relay in Heat, the O/B switch must be moved to the B position.

INSTALLER MENU

To prevent changes that may affect system performance, this thermostat has an INSTALLER'S
MENU and a USER MENU. The INSTALLER'S MENU provides access to every option, while the
USER MENU provides access to items that will not affect system performance. To access the
INSTALLER'S MENU press the Menu button for 8 seconds. The display will show item 30 in the
table below. Use Next and Back to navigate through menu items. Press
menu setting.
Installer's Menu #
(Hold Menu 8 Seconds)
30
32
35
50
60
65
66
74
76
(Installer Menu continued on next page)
Description
Heat Cycle Rate (how often
the heat will turn on)
Aux Cycle Rate (how often the
auxiliary heat will turn on)
Cool Cycle Rate (how often
the cooling will turn on)
Compressor Lockout
(protects the compressor
from short cycling)
Duel Fuel Logic (turn On when using
gas as the auxiliary heat source)
Maximum Heat Limit
(maximum set point for heat mode)
Minimum Cool Limit
(minimum set point for cool mode)
Schedule Type (set as either 7-Day,
5-1-1 Day or Non-Programmable)
Early Start (starts heating or
cooling early so your programmed
temperature is reached by the
programmed time)
Settings
Default Setting
(flashing icons)
(Press
SLO – slow
MEd
MEd – medium
FAS – fast
SLO – slow
MEd
MEd – medium
FAS – fast
SLO – slow
MEd
MEd – medium
FAS – fast
On – 5 minute delay
OFF
OFF – no delay
On- gas auxiliary heat
OFF
OFF- electric auxiliary heat
99
47 to 99
45
45 to 97
7 – 7 Day
5
5 – 5-1-1 Day
0 – Non Programmable
On – start early
OFF
OFF – start at program
period time
1
2
or
to change a
or
)
3