MAX-E-PRO
POOL AND SPA PUMP
INSTALLATION AND USER'S GUIDE
© 2020 Pentair. All rights reserved.
1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000
S764 Rev. D 3/9/20
STA-RITE
®
5P6R Series MODELS
HP
1 Phase
3/4
5P6R6D-209
1
5P6R6E-210
1-1/2
5P6R6F-211
2
5P6R6G-212
3
5P6R6H-213
This manual should be given to the owner of this pump.
3 Phase
5P6R6D3-209
5P6R6E3-210
5P6R6F3-211
5P6R6G3-212
5P6R6H3-213

Advertisement

loading

Summary of Contents for Pentair STA-RITE MAX-E-PRO 5P6R Series

  • Page 1 5P6R6H-213 5P6R6H3-213 This manual should be given to the owner of this pump. © 2020 Pentair. All rights reserved. 1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000 S764 Rev. D 3/9/20...
  • Page 2 230 VAC charge even when there is no power to the unit. This guide provides installation and operation instructions for this pump. Consult Pentair with any questions regarding this equipment. • The pump is not submersible. • The pump is capable of high flow rates; use caution when installing and...
  • Page 3 IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS HAZARDOUS PRESSURE: STAND CLEAR OF PUMP TO MINIMIZE THE RISK OF INJURY DUE TO SUCTION ENTRAPMENT HAZARD: AND FILTER DURING START UP. Circulation systems operate under high pressure. When • A properly installed and secured ANSI/ASME A112.19.8 approved anti- any part of the circulating system (i.e.
  • Page 4: Table Of Contents

    ‘5P6R’ SERIES II PUMP IMPORTANT SAFETY INSTRUCTIONS WITH TRAP To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS Always follow basic safety precautions with this MANUAL CAREFULLY! equipment, including the following. The Sta-Rite ‘5P6R’...
  • Page 5: Installation

    • Release all air in system before testing. INST ALLA TION • Water pressure for test must be less than 25 PSI Only qualified, licensed personnel should install pump (7.5 kg/cm and wiring. • Water Temperature for test must be less than 100 Pump mount must: Be located away from corrosive or flammable •...
  • Page 6: Pool Pump Suction Requirements

    Entrapment Protection valves in suction and discharge pipes. The pump suction system must provide protection For most installations Pentair recommends installing a against the hazard of suction entrapment or hair valve on both the pump suction and return lines so that entrapment/entanglement.
  • Page 7 Outlets Per Pump Provide at least two hydraulically balanced main drains, with covers (see below), for each swimming pool pump suction line. The centers of the main drains (suction fittings) must be at least three feet apart. The system must be built so that it cannot operate with the pump drawing water from Hazardous voltage.
  • Page 8: Electrical Installation

    2008 to current NEC Standards for Pool Pumps. the pump should be wired on its own independent circuit See Pentair product catalog for details. unless the pump is operated in tandem with a Pentair salt chlorine generator. Section P/N 350486 Rev. E 3/9/20...
  • Page 9: Operation

    OPERA TION discharge valves are opened. If pump is not in a flooded suction system, remove trap NEVER run pump dry. If the pump is run dry, the cover handle ring and trap cover; fill trap and pump with mechanical seal will be water.
  • Page 10: Pump Service

    Draining Pump Startup For Winterized Equipment 1. Pump down water level below all inlets to the pool. 1. Remove any temporary weather protection placed around system. To avoid dangerous or fatal electrical shock 2. Follow filter hazard, turn OFF power to motor before draining manufacturer’s pump.
  • Page 11 If shaft seal is worn or damaged, repair as follows: 4. Remount seal plate on motor. Tighten bolts to 60- 80 inch-lbs. (69-92 Pump Disassembly/Removing Old Seal kg/cm) torque. Disconnect power to pump motor. 5. Apply a small amount of liquid detergent to Be sure gate valves on suction and return piping inside diameter of...
  • Page 12: Troubleshooting Guide

    TROUBLESHOOTING Electrical: GUIDE 9. Pump may be running too slowly; check voltage at Read and understand safety and operating motor terminals and at instructions in this manual before doing any work meter while pump is on pump! running. If low, see wiring instructions or consult Only qualified personnel should electrically test power company.
  • Page 13: Repair Parts List

    5P6R SERIES 50 Hz. MAX-E-PRO POOL PUMP 3/4 and 1 HP See Box A See Box A 4285 1102 REPAIR PARTS LIST Part Part Box A Description Qty. Motor Chart at Right For quick disconnect pipe connections, purchase separately: #10-32 x 1/2” Screw U30-692SS Pkg.
  • Page 14 5P6R SERIES 50 Hz. MAX-E-PRO POOL PUMP 1-1/2 and 2 HP See Box A See Box A 4285 1102 REPAIR PARTS LIST Part Part Description Qty. Motor Chart at Right Box A #10-32 x 1/2” Screw U30-692SS Bonding Lug U17-568 For quick disconnect pipe Water Slinger 17351-0009...
  • Page 15 Model 5P6R6H-213 and 5P6R6H3-213 MAX-E-PRO POOL PUMP 3 HP See Box A See Box A REPAIR PARTS LIST 4285 1102 Part Part Description Qty. Motor 230V/50H/1 Ph (5P4R6H) 62003-2077 Motor 220-240/380-415V/50H 3 Ph (5P4R6H3) 62003-2078 Box A #10-32 x 1/2” Screw U30-692SS Bonding Lug U17-568...
  • Page 16 WWW.PENTAIR.COM All indicated Pentair trademarks and logos are property of Pentair Inc. or its global affiliates in the U.S.A and/or other countries. Third party registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.