Prince Castle McDonald's 625-MFY Operation Manual

Hide thumbs Also See for McDonald's 625-MFY:

Advertisement

Quick Links

Operation
Operation
Manual
Manual
On/Off Rocker Switch
(left-side of unit)
Spatula
Control Panel
LIMITED WARRANTY
This product (with the exception of the water tube, part no. 625-197S) is
warranted to be free from defects in material and/or workmanship for a period
of two (2) years from date of original installation, not to exceed 30 months from
date of shipment from our factory. P.C. Boards and Heater Assemblies are
warranted for three (3) years from date of installation, not to exceed 42 months
from date of shipment. Any component which proves to be faulty in material
and/or workmanship will be replaced or repaired (at the option of Prince
Castle, Inc.) without cost to the customer for parts or labor. This warranty
covers on location service (i.e. trip charges and/or mileage). Travel mileage
is limited to 100 miles (200 kilometers) round trip (one trip warranty) from an
authorized service agency or its sub-service agency.
This warranty is subject to the following exceptions/conditions:
• Use of any non-genuine Prince Castle parts voids this warranty.
• All labor shall be performed during regular work hours. Overtime premi-
um will be charged to the buyer.
• Damage caused by carelessness, neglect, and/or abuse (e.g., dropping,
tampering or altering parts, equipment damaged in shipment, by fire,
flood or an act of God) is not covered under this warranty.
Steamer 625-505 Rev G

Product Identification

External Meter Plug Inlet
(for calibration)
SANITATION
355 East Kehoe Blvd. • Carol Stream, IL 60188
Phone: 630-462-8800 • Toll Free: 1-800-PCASTLE
Fax: 630-462-1460 • www.princecastle.com
Temperature &
UP Arrow Button
Prince Castle
Logo Button
Product
LED Display
Buttons
(1 thru 4)

TABLE OF CONTENTS

Product Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Temperature Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
View Firmware Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Manual Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Programming Product Name & Water Cycle . . . . . . . . . . . . . . . . . . . . . . . .4
Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Cleaning - Monthly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Exploded View and Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Steamer
Steamer
625-MFY
625-MFY
Celsius/Fahrenheit &
DOWN Arrow Button
McDonalds
Logo Button
Start Button
Printed in USA 1010 © 2003

Advertisement

Table of Contents
loading

Summary of Contents for Prince Castle McDonald's 625-MFY

  • Page 1: Table Of Contents

    Programming Product Name & Water Cycle ......4 • Use of any non-genuine Prince Castle parts voids this warranty.
  • Page 2: Safety Information

    • save carton and packaging materials for inspection purposes All electrical connections must be in accordance with local electrical • contact your local dealer, or if purchased directly, the Prince Castle codes and any other applicable codes. Sales Department at 800-722-7853 or 1-630-462-8800 to arrange for a Plug the unit into an applicable electrical receptacle.
  • Page 3: Temperature Calibration

    . Replace the manual reset cap. NOTE: If the unit continues to shut-off due to overheating, contact your authorized Prince Castle Service Agency. Manual Reset . VERS XX.XX Steamer 625-505 Rev G Printed in USA 1010 ©...
  • Page 4: Programming Product Name & Water Cycle

    PROD12 – – – – FILET Press and hold the Prince Castle LOGO button first, then press B. Press the UP or DOWN Arrow button to scroll through the and hold the McDonald’s LOGO button for 6 seconds. product selections.
  • Page 5: Error Messages

    Steamer 625-MFY The display now shows the product’s number of on-off water A. Press the UP or DOWN Arrow buttons to change the valve valve cycles. OFF time. B. Press the McDonald’s LOGO button to store the new valve OFF time. NOTE: Pressing the Product 3 button at any time exits the Program mode without storing the change.
  • Page 6: Cleaning - Daily

    Steamer 625-MFY Cleaning - Daily PM Tasks The following equipment is required: WARNING Turn the unit off and unplug the power cord from the electrical recep- • All Purpose Super Concentrate (APSC) ® tacle. Proceed with caution, unit is still hot! •...
  • Page 7: Cleaning - Monthly

    Steamer 625-MFY Cleaning - Monthly PM Tasks The following equipment is required: WARNING Turn the unit off and unplug the power cord from the electrical recep- • All Purpose Super Concentrate (APSC) ® tacle. Proceed with caution, unit is still hot! •...
  • Page 8: Exploded View And Parts List

    Steamer 625-MFY Exploded View and Parts List Ref. Part No. Description Qty. Spatula Assembly Spatula Assembly Spatula Assembly 625-129S 625-129S 625-129S 78-233S 78-233S 78-233S Switch, Rocker, 20A Switch, Rocker, 20A Switch, Rocker, 20A 625-043S 625-043S 625-043S Membrane Switch Assembly Membrane Switch Assembly Membrane Switch Assembly 625-158S 625-158S...
  • Page 9: Wiring Diagram

    TROUBLESHOOTING GUIDE PROBLEM PROBABLE CAUSE REMEDY Unit will not heat up; “DISPLAY” Loose connections Check continuity wiring is lit. On/Off switch is ON Unit heats up but will not steam. Water supply is not connected Disconnect water line and check if water is flowing Display reads “REMOVE”...
  • Page 11 What You Need To Know About Your New Steamer Operation - Steams two (2) buns in 11 seconds - To steam your buns: 1) After the steamer has warmed up and the display Operation Tips reads, “FILET,” load buns CUT SIDE DOWN on - Steamed buns should have an spatula.
  • Page 12 355 East Kehoe Blvd. ! Carol Stream, IL 60188 Tel: (630) 462-8800 ! Fax: (630) 462-1460 Toll Free: 1-800-PCASTLE Printed in October 2003 625-512 www.princecastle.com Prince Castle Inc.
  • Page 13 CAUTION: Platen must be cool. 355 East Kehoe Blvd. l Carol Stream, IL 60188 Printed in November 2003 Tel: (630) 462-8800 l Fax: (630) 462-1460 625-511revA Prince Castle Inc. Toll Free: 1-800-PCASTLE www.princecastle.com...
  • Page 14 Set both steamers’ regulators to 25 psi. 355 East Kehoe Blvd. l Carol Stream, IL 60188 Tel: (630) 462-8800 l Fax: (630) 462-1460 Toll Free: 1-800-PCASTLE Printed in December 2003 625-514 revB www.princecastle.com Prince Castle Inc.
  • Page 15 Steamer 625-MFY Notes Printed in USA 0731 © 200 3 Steamer 625-505 Rev G...
  • Page 16 STEAMER System: Maintenance Requirement Card (MRC) Prince Castle: Rapid Steamer Series Precaution Hazard Communication Standard (HCS) - The procedure(s) in this manual include the use of chemical products. These chemical products will be highlighted with italic-faced letters followed by the abbreviation (HCS). See...
  • Page 17 Monthly Cleaning When Monthly 1. Turn unit power On/Off switch to OFF position and unplug steamer from power source. “PROCEED WITH CAUTION” – CAUTION UNIT IS STILL HOT Tools 2. While wearing protective gloves, remove top cover, top cover plate and venturi plate and wash the in a solution of McD®...

Table of Contents