[1] TROUBLESHOOTING TABLE
Is the AC cord connector tightly connected to the set?
Is the output voltage at pin(8) of P9601(BU+5V)?
Are the wire harnesses and other cables properly connected in
the set?
Is there the PS-ON signal and PNL-POWsignal input at pin(4)
and (6)of P9601?
Is the output voltage of each pin on P9601 as prescribed?
pin8
5V
pin11 and 12 15V
Are the DC/DC converter outputs and the output voltages along
the control line? (SUB)
5V (IC402,Q402)
1.5V(IC403)
9V (IC404)
B3.3 (IC405)
5V (IC406)
Are the DC/DC converter outputs and the output voltages along
the control line? (MAIN)
3.3V (Q9607, IC9601, etc.)
1.8V(Q9609, IC9606, etc.)
1.3V(Q9610, IC9603, etc.)
5V(IC9602)
2.5V(IC9605)
1.2V(Q9606, IC9604, etc.)
BU3.3V(IC1805)
No power or no startup.
YES
YES
YES
YES
YES
YES
Service Manual
NO
Reconnect the Ac cord tightly and turn on the power again.
NO
Replace the power unit (RDENCA237WJQZ) and ac inlet unit
(RUNTKA341WJQZ).
NO
Reconnect the wire harnesses and other cables properly set.
NO
Check the PS ON signal line PNL POW signal line.
NO
Replace the power unit (RDENCA237WJQZ) and ac inlet unit
(RUNTKA341WJQZ).
NO
Check the DC/DC converters and control line.
NO
Check the DC/DC converters and control line.
6 – 1