Circuit Operation (Handset) - Panasonic KX-TGE210B Service Manual

Digital cordless phone
Hide thumbs Also See for KX-TGE210B:
Table of Contents

Advertisement

3.1.2.

Circuit Operation (Handset)

[Changed from original section "4.9. Circuit Operation (Handset)"]
3.1.2.1.
Outline
Handset consists of the following ICs as shown in Block Diagram (Handset) (P.5).
• DECT BBIC (Base Band IC): IC1
- All data signals (forming/analyzing ACK or CMD signal)
- All interfaces (ex: Key, Detector Circuit, Charge, DC/DC Converter, EEPROM, LCD, RF Power Amp.)
- PLL Oscillator
- Detector
- Compress/Expander
- Reception
- Integrated 1.9 GHz PA for DECT
• QSPI FLASH MEMORY: IC4
- Main Program D/L Area
• EEPROM : IC3
Following information data is stored
- Settings
ex : ID code, user setting
3.1.2.2.
Power Supply Circuit/Reset Circuit
Circuit Operation:
When power on the Handset, the voltage is as follows;
BATTERY(2.2 V ~ 2.6 V: BATT+) -> Q1 (1.8 V), IC1-44pin (CP3V)
The Reset signal generates IC1 (71 pin) and 1.8 V.
3.1.2.3.
Charge Circuit
Circuit Operation:
When charging the handset on the Base Unit, the charge current is as follows;
DC+(5.5 V) -> R371 -> R372 -> D362 -> CHARGE+(Base) -> CHARGE+(Handset) ->
BATTERY- -> R45 -> GND -> CHARGE-(Handset) -> CHARGE-(Base) -> GND -> DC-(GND)
In this way, the BBIC on Handset detects the fact that the battery is charged.
The charge current is controlled by switching Q9 of Handset.
Refer to Power Supply Circuit/Reset Circuit (P.6).
3.1.2.4.
Battery Low/Power Down Detector
Circuit Operation:
"Battery Low" and "Power Down" are detected by BBIC which check the voltage from battery.
The detected voltage is as follows;
• Battery Low
Battery voltage: V(Batt)
The BBIC detects this level and "
• Power Down
Battery voltage: V(Batt)
The BBIC detects this level and power down.
Battery +
1.8V
Reset
(IC1_71 pin)
2.25 V ± 50 mV
" starts flashing.
2.0 V ± 50 mV
6
Q2
-> Q3 -> BATTERY+... Battery...
R8

Hide quick links: