For the minimal distances of fitting check the table.
D
Minimum distances
Dimension
A
B
C
D
E
F
GAS BURNERS
BURNER
Auxiliary
Semi-rapid
Rapid
GAS CONNECTION
Use a flexible pipe in compliance with the
regulation in force. Make sure they do not come in
touch with mobile parts and are not squeezed.
A
E
F
B
C
mm
650
450
2
400
150
less than 400
NORMAL POWER kW
1
1.9
2.8
LEVELLING OF THE APPLIANCE
Use small feet on the bottom of appliance to set the
appliance top surface level with other surfaces.
OTHER TECHNICAL DATA
WARNING! These instructions are
only valid in the countries whose
symbols appear on this booklet's
cover.
Gas category:
Gas supply:
Voltage:
Frequency:
Natural Gas
INJECTOR MARK 1/100 mm
70
96
119
WARNING! Only a qualified and
competent person can do the gas
installation.
Before you connect te gas, disconnect
the appliance from the electricity
supply or switch off the fuse in the
fuse box. Close the primary valve of
the gas supply.
I2H
G20 (2H) 20 mbar
220-240 V
50 Hz
Btu/h
3412
6483
10236
7