Fans; Replacing The Cooling Fan - ABB ACS880-7407LC Hardware Manual

Semiconductor switch units
Table of Contents

Advertisement

40 Maintenance

Fans

Replacing the cooling fan

WARNING!
Obey the safety instructions of the drive. If you ignore them, injury or death,
or damage to the equipment can occur. If you are not a qualified electrical
professional, do not do installation or maintenance work.
WARNING!
Use the required personal protective equipment. Wear protective gloves and long
sleeves. Some parts have sharp edges.
1. Repeat the steps described in section
2. Remove any shrouding in front of the cooling fan in case of marine construction (+C121).
3. Disconnect the fan wiring.
4. Undo the two retaining screws (a).
5. Pull the fan outwards to separate it from the heat exchanger housing.
6. Install new fan in reverse order. Align the guide pins (b) at the rear of the fan cowling
with the slots (c) in the module bottom guide, then reinstall the retaining screws (a).
a
Electrical safety precautions (page
24).
c
b

Advertisement

Table of Contents
loading