Troubleshooting Instructions
Power control loop
Basically, the power detection is done with the Power detector module and power con-
trol is done inside the Taco. Power detection is basically similar for both bands, except
that both bands have their own coupler.
Is PWRDET vs output
power OK?
See chart below.
Y
Is DAC value vs.
PWRDET (mV) OK?
The detected voltages are illustrated in the following table and diagram:
800A
Pout
PL
dBm
dac
2
24.8
712
3
21.6
512
4
18.5
340
5
14.5
239
6
10.5
180
7
6.5
141
8
-
-
9
-
-
§0
-
-
Note: DAC values may vary about +- 20%
Note: TXPWRDET is the difference between TX on burst and off burst.
Page 32
Check VR2 and
RFTEMP. Check
N
C930, C931, and
PWRDET module.
Check UEM
N
(baseband)
Figure 14: Fault tree: Power control loop
800D
TXPWRDET
Pout
mV
dBm
1984
27.3
1437
23.3
961
19.3
686
15.3
510
11.3
415
7.3
-
3.3
-
-0.7
-
-4.7
Nokia Corporation
CCS Technical Documentation
TXPWRDET
dac
Mv
779
2201
476
1312
284
759
171
462
98
271
56
151
30
84
14
46
5
16
Confidential
Note! See PWRDET vs
Output power curve
1900D
Pout
TXPWRDET
dBm
dac
mV
27.3
702
1980
23.3
431
1198
19.3
262
730
15.3
158
445
11.3
88
253
7.3
50
148
3.3
26
79
-0.7
14
44
-4.7
6
20
Issue 2 09/2003