Troubleshooting-Screen/Leds/Control Panel - Monessen Hearth Artisan AVFL Series Owner's Manual

Table of Contents

Advertisement

C. Troubleshooting – Screen/LEDs/Control Panel
SYMPTOM
LED lights will not turn
on (appliance or control
panel)
Appliance does not
turn on when control
panel on/off switch is
depressed
POSSIBLE CAUSE
Check that GFCI breaker is operating as intended and is
not tripped. Verify that AC power has been connected to
No AC power to ap-
the appliance. Ensure that both the 4V IPI control module
pliance
power supply as well as the LED power supply are securely
plugged into the appliance junction box.
Check appliance for loose/corroded connections or shorted
Faulty wiring
wires.
Check for 12VDC from power supply. If 12VDC is present,
LED failure
LED strip is bad.
Check for 12VDC. If no 12VDC is present, power supply is
Power supply failure
bad
Control panel failure
Replace switch assembly
Check that GFCI breaker is operating as intended and is
not tripped. Verify that AC power has been connected to
No AC power to ap-
the appliance. Ensure that both the 6V IPI control module
pliance
power supply as well as the LED power supply are securely
plugged into the appliance junction box.
Check appliance for loose/corroded connections or shorted
Faulty wiring
wires.
Control panel failure
Replace control panel
Monessen • AVFL Series Owner's Manual • 4099-900 Rev. C • 06/21
CORRECTIVE ACTION
25