28 II Ex
Calibration Information
Step
Function
14
AC Volts
15
Frequency
16
Sensitivity
17
18
Trigger level
19
Duty Cycle
20
DC Volts
21
22
23
24
25
DC Volts
26
Ohms
27
28
29
30
31
nS
32
Conductance
33
Diode
34
AC Amps
35
DC Amps
36
AC Milliamps
37
38
DC Milliamp
39
40
41
AC Microamps
14
Table 5. Accuracy Tests (cont.)
Test
Range
600 mV
600 mV
6 V
60 V
6 V
6 V
6 V
60 V
600 V
1000 V
600 mV
600 mV
600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
50 MΩ
60 nS
6 V
6 A
6 A
60 mA
400 mA
60 mA
400 mA
600 μA
6000 μA
5520A Output
150 mV, 99.95 kHz
150 mV, 199.50 kHz
0.7 V, 99.95 kHz
7 V, 99.95 kHz
3.4 V, 1 kHz Sq. Wave
5 V, 1 kHz, DC offset 2.5 V
Square Wave
3.3 V dc
33 V dc
330 V dc
1000 V dc
50 mV dc
330 mV dc
330 Ω ( Use 2 wire Comp)
3.3 kΩ (Use 2 wire Comp)
33 kΩ
330 kΩ
3.3 MΩ
30 MΩ
100 MΩ
2.0 V dc
3.0 A, 60 Hz
3.0 A
33 mA, 60 Hz
330 mA, 60 Hz
33 mA
330 mA
330 μA, 60 Hz
3300 μA, 60 Hz
UUT Measurement
Low Limit
High Limit
99.93 mV
99.97 mV
199.48 mV
199.52 mV
99.93 V
99.97 V
99.93 V
99.97 V
999.8 V
1000.2 V
49.7 %
50.3 %
3.297 V
3.303 V
32.97 V
33.03 V
329.7 V
330.3 V
998 V
1002 V
49.8 mV
50.2 mV
329.6 mV
330.4 mV
329.1 Ω
330.9 Ω
3.292 kΩ
3.308 kΩ
32.92 kΩ
33.08 kΩ
327.2 kΩ
332.1 kΩ
3.279 MΩ
3.321 MΩ
29.67 MΩ
30.33 MΩ
9.60 nS
10.40 nS
1.959 V
2.041 V
2.968 A
3.032 A
2.990 A
3.010 A
32.65 mA
33.35 mA
326.5 mA
333.5 mA
32.89 mA
33.11 mA
329.1 mA
330.9 mA
326.5 μA
333.5 μA
3265 μA
3335 μA