14:40
This heater has Electronic Climate Control which automatically monitors and selects
the ideal power setting to maintain your chosen temperature.
If the selected temperature is higher than the actual room temperature, the appliance
will start automatically and rapidly heat the room until it reaches the selected tempe-
rature. The unit will automatically maintain the temperature at a constant level, by
switching between maximum, medium, minimum power and OFF.
If medium power level has been selected using the "ON MODE" button, the
appliance will modulate between medium, minimum power and OFF to maintain a
selected temperature.
ANTI-FREEZE SETTING
Press the "ON MODE" button and it is recommended to select the maximum power
level. Set the temperature to 42°F with the "-" button. When set in this way, the
appliance will switch on automatically only if the room temperature falls below 42°F,
to prevent freezing, at minimum energy consumption.
N.B.This function is not guaranteed in the event of power failures, lasting more than
2 minutes.
3) PROGRAMMING THE ELECTRONIC TIMER
The timer allows you to set 2 programmes in a 24 hour period to programme the
timer.
1-Press the button "
me A). The yellow timer ON lamp will light up.
2 Set the start time for your programme by pressing the "HOUR" button to set the
hour and the "MIN" button to set the minutes.
3-To select how long you require the heater to be on, push "+min" button and push
repeatedly until your chosen operating timespan appears. The time periods you
are able to choose from are (30', 45', 1hr, 2hr, 4hr,8h -max).
AM
AUTO
:
O
Pagina 5
AUTO" (fig. 5), this accesses the 1st programme (program-
AM
AUTO
MAN
:
° F
0
AM
AUTO
:
O
Fig. 5
AUTO
° F
0
5