LG LDE4413ST Service Manual page 66

Freestanding electric range
Hide thumbs Also See for LDE4413ST:
Table of Contents

Advertisement

Sensing Fail, F1 (F4), F2 (F5)?
Unplug the unit
1
Is the Connector disconnected
or loose?
(1) Sensor connection
(2) CN60 and CN61 of Main
PCB
Upper
Sensor
connection
No
TROUBLESHOOTING
Reconnect or adjust
Yes
the connection
Lower
Sensor
connection
CN61
CN60
2
Is the resistance of
thermistor normal?
Check:
Pins 4 and 5 of CN60 and pins 5 and 6 of
CN61 in main PCB
Normal- approximately 1.09kΩ at 25℃
Yes
7-14
Replace the
No
defective
Thermistor
CN61
CN60

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lde4413bd

Table of Contents