Dell PowerEdge 6850 Information Update page 8

Dell poweredge 6850 servers: supplementary guide
Hide thumbs Also See for PowerEdge 6850:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Table 1-2. LCD Status Messages (continued)
Line 1
Line 2
Message
Message
E1000
FAIL SAFE
E1000
MISCONFIG
E0119
TEMP AMBIENT
E0119
TEMP PROC #
E0119
TEMP PLANAR
E0212
PROC VTT
VOLT PG n
E0212
VOLT PG n Video
E0212
E0212
VOLT BATT ROMB
6
Information Update
Causes
Failsafe event.
Missing or improperly installed
VRMs.
Ambient system temperature is
out of acceptable range.
The specified processor is out of
acceptable temperature range.
System board temperature is out
of acceptable temperature range.
Processor VTT voltage is out
of acceptable voltage range.
System power supply is out of
acceptable voltage range; faulty
or improperly installed power
supply.
Video voltage is out of acceptable
voltage range.
Faulty RAID battery.
Corrective Actions
Capture the event log and
see "Getting Help" in your
Installation and Troubleshooting
Guide.
See "Installing a Processor VRM"
in your Installation
and Troubleshooting Guide. If the
VRMs appear to be properly
configured and installed, see
"Getting Help" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting Power
Supplies" in your Installation
and Troubleshooting Guide.
See "Troubleshooting Power
Supplies" in your Installation
and Troubleshooting Guide.
See "Getting Help" in your
Installation and Troubleshooting
Guide.
Replace the RAID battery.
See "Activating the Optional
Integrated RAID Controller"
in your Installation
and Troubleshooting Guide.

Advertisement

Table of Contents
loading

Table of Contents