Fault
Refill indicator for rinse aid
does not light up.

Malfunctions

Fault
Water is left in the appliance
at the end of the pro-
gramme.
Appliance cannot be
switched on or operated.
Appliance does not start.
Programme starts automat-
ically.
Appliance stops during the
programme or cuts out.
Cause
Rinse aid system is switched
off.
Cause
Filter system or area under
the filters is blocked.
Programme has not yet
ended.
Software update is taking
place.
Appliance functions have
failed.
The mains fuse has tripped.
Mains cable is not inserted.
Appliance door is not closed
properly.
You did not wait until pro-
gramme ended.
Appliance door is not closed
properly.
Power and/or water supply
has been interrupted.
Top basket is pressing
against inner door and pre-
venting appliance door from
being closed securely.
Troubleshooting en
troubleshooting
Set the amount of rinse aid to be
dispensed.
troubleshooting
Clean the "Filters" → Page 44.
1.
Clean the "Wastewater pump"
2.
→ Page 59.
Wait until the programme ends or
cancel the programme with Reset.
→ "Terminate programme",
Page 36
Wait until the software update has
finished.
Pull out the mains plug or switch off
1.
the fuse.
Wait at least 2 minutes.
2.
Connect the appliance to the power
3.
supply.
Switch the appliance on.
4.
Check the relevant fuse.
Check whether the socket works.
1.
Check whether the mains cable is
2.
properly inserted in the socket and
on the rear of the appliance.
Close the appliance door.
→ "Terminate programme",
Page 36
Close the appliance door.
Check the power supply.
1.
Check the water supply.
2.
Check whether the rear panel of the
appliance is being pressed in by a
socket or hose holder that has not
been removed.
57