Rear Panel Features Description
1. AC Mains Input
Connect the IEC 14 Gauge 12' (4m) power cord to a 15A 120VAC outlet to provide power to the AP-S15RTHR.
2. AC Mains Input IEC Power Cord Retainer
The AP-S15RTHR incorporates an IEC Power Cord retainer bracket to prevent the cord from coming loose. See IEC power cord retainer
bracket installation.
3. AC Power Outlets
The AP-S15RTHR features six NEMA 5-15P AC outlets. There is one Unswitched outlet on the front and one on the rear of the unit.
There are four Switched AC outlets on the rear of the unit for a total of six AC outlets. These four Switched AC outlets are "Live" when
the front panel power switch is in the On position and the Remote Turn On terminals are shorted. The two Unswitched outlets are
always live if the power cord is connected to 120VAC.
4. Remote Activation
There are two methods to remotely activate the AP-S15RTHR:
A. External Switch - The Ext SW terminals are connected to a latching type dry contact closure to activate the AP-S15RTHR.
Note: This feature can be used for Emergency Power Down (EPD), when tied into a normally closed latching contact closure
(e.g. Fire Panel).
B. DC Voltage - When you apply 5V - 24VDC to the Return terminal the unit will activate. See "Remote Activation Drawings" for
details. It may be required to connect a Ground Pin from the AP-S15RTHR to the DC sending unit.
5. DC Voltage Output 24V 2000mA
The AP-S15RTHR features a 24VDC 2000mA output to power external devices. This 24VDC output provides enough current to power
several of the Time Saving Device (TSD) preamps, mixers or amplifiers reducing or eliminating the need for external DC power supplies.
The DC output works in conjunction with the Switched AC outlets. There two sets of DC - & + connections in parallel for convenience.

Installation

Before installing, read the entire manual to ensure proper understanding of operation and that all features are being utilized. The
AP-S15RTHR can be placed on a shelf or rack mounted in a half width rack or a 19" width rack. When rack mounted, placement within
the rack is flexible however the AP-S15RTHR should be within 6' of a dedicated 15A AC outlet. When rack mounting, use rack rail type
screws of
" x 1". Always make sure the 15A outlet is properly inspected by a certified electrician prior to connecting the AP-S15RTHR.
10
32
Make sure to inspect the equipment that will be connected to the AP-S15RTHR to ensure it does not exceed 15A total amperage draw.