Maintenance and Adjustments

Cleaning Intervals

The following table outlines the recommended maintenance schedule for the various printer
parts.
Area
Printhead
Platen Roller
Peel-Off
Rollers
Media Path
Peel/Tear Bar
Media Sensor
Exterior
Interior
* It is recommended that a solvent containing isopropyl alcohol be used.
Isopropyl alcohol is a flammable solvent, always take the proper precautions
when using this substance.
Method
Turn off the printer before cleaning the
printhead. Use solvent* on a cotton swab to
clean the printhead from end to end.
Turn the power off.
and clean it thoroughly with solvent* and a
cotton swab.
Rotate the peel-off rollers and clean it
thoroughly with solvent* and a cotton swab.
Solvent*
Solvent*
Compressed Air
Mild detergent or desktop cleaner.
Brush or vacuum
Remove the platen roller
22
Interval
After every roll of media.
After every roll of media.
After every roll of media.
After every roll of media.
As needed
Monthly
As needed
As needed.