Problem
The lamp does not work.
The compressor operates
continually.
There is too much frost and
ice.
The compressor does not
start immediately after
pressing the ActionFreeze,
or after changing the tem-
perature.
Temperature cannot be set. The ActionFreeze function
The temperature in the ap-
pliance is too low/too high.
Possible cause
The valve is blocked.
The lamp is defective.
Temperature is set incor-
rectly.
Large quantities of food to
be frozen were put in at the
same time.
The room temperature is
too high.
Food placed in the appli-
ance was too warm.
The lid is not closed proper-
ly.
The ActionFreeze function
is switched on.
The lid is not closed cor-
rectly or the gasket is de-
formed/dirty.
The water drainage plug is
not correctly positioned.
Temperature is set incor-
rectly.
This is normal, no error has
occurred.
is switched on.
The temperature regulator
is not set correctly.
The lid is not closed cor-
rectly.
The products' temperature
is too high.
Many products are stored
at the same time.
ENGLISH
Solution
Check the valve.
Refer to "Replacing the
lamp".
Refer to "Operation" chap-
ter.
Wait some hours and then
check the temperature
again.
Refer to climate class chart
on the rating plate.
Allow food to cool to room
temperature before storing.
Check if the lid closes well
and the gaskets are un-
damaged and clean.
Refer to "ActionFreeze
function".
Refer to "Opening and clos-
ing the lid".
Position the water drainage
plug in the correct way.
Refer to "Operation" chap-
ter.
The compressor starts after
a period of time.
Refer to "ActionFreeze
function".
Set a higher/lower tempera-
ture.
Refer to "Opening and clos-
ing the lid".
Let the product tempera-
ture decrease to room tem-
perature before storage.
Store less products at the
same time.