Led systems power supply, 24 volt

Advertisement

Quick Links

GE
Lighting Solutions
Tetra
LED Systems Power Supply
®
(GEPS24-180U)
Power Supply Features
• Supports Tetra PowerStrip DS, Tetra miniStrip DS, Tetra EdgeStrip,
Tetra Contour and Tetra Contour LS LED lighting systems
• Class 2 wiring per NEC Article 725 (SELV)
• Damp location rated
• IP66 rated: separate enclosure required
BEFORE YOU BEGIN
Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing or
installing product.
• Properly ground Tetra
power supply.
®
RISK OF FIRE:
• Use only Tetra
supply wire to make connection from Tetra
®
supply to Tetra
LED strip.
®
• Use only approved wire for input/output connection.
Minimum size 18 AWG (0.82 mm
• Follow all local codes.
Power Supply Installation
Mount LED driver and remove
1
junction box cover. Carefully remove
knockout for AC line input wires. Install
appropriate electrical fittings in the
knockout holes for wire protection.
imagination at work
WARNING/AVERTISSEMENT
power
®
)
2
To LED system
Output wires
Connect the supply wire that is
2
attached to your LED system to the
red (+) and black (-) output wires
of the LED driver as outlined in the
"Electrical Connections" section
of your LED system's Installation
Instructions.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l'alimentation électrique à la boîte de fusibles ou au
disjoncteur avant l'entretien ou l'installation du produit.
• Assurez-vous de correctement mettre à terre l'alimentation
électrique Tetra
.
®
RISQUES D'INCENDIE
• N'utilisez que le fil d'approvisionnement Tetra
connexion entre l'alimentation Tetra
• N'utilisez que des fils approuvés pour les entrées/sorties de
connexion. Taille minimum 18 AWG (0.82 mm
• Respectez tous les codes locaux.
Green with
yellow
stripe
(ground)
White (neutral)
3
Installation Guide
pour faire la
®
et la bande DEL Tetra
.
®
®
).
2
AC line
Black (line)
Connect the AC line to the black
(line) and white (neutral) input
wires of the LED driver using
18-14 AWG (0.82-2.08 mm
2
twist-on wire connectors.
Ground LED driver by connecting
green wire with yellow stripe
to grounding screw. Replace
junction box cover.
24
Volt
)

Advertisement

loading

Summary of Contents for GE Tetra GEPS24-180U

  • Page 1 Installation Guide Lighting Solutions Volt Tetra LED Systems Power Supply ® (GEPS24-180U) Power Supply Features • Supports Tetra PowerStrip DS, Tetra miniStrip DS, Tetra EdgeStrip, Tetra Contour and Tetra Contour LS LED lighting systems • Class 2 wiring per NEC Article 725 (SELV) •...
  • Page 2 1 - 8 8 8 - 6 9 - 4 3 - 5 3 3 GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company.