Craftsman 137.322850 Operator's Manual page 11

7-1/4 in. compact slide miter saw with laser trac
Table of Contents

Advertisement

3. If the tool suddenly stalls while
cutting wood, release the trigger
switch, unplug the tool, and free the
blade from the wood. The saw may
now be started and the cut finished.
4. FUSES may "blow" or circuit
breakers may trip frequently if:
a. MOTOR is overloaded –
overloading can occur if you feed
too rapidly or make too many
start/stops in a short time.
b. LINE VOLTAGE is more than
10% above or below the
nameplate voltage rating. For
heavy loads, the voltage at
motor terminals must equal the
voltage specified on the nameplate.
c. IMPROPER or dull saw blades
are used.
5. Most motor troubles may be traced
to loose or incorrect connections,
overload, low voltage or inadequate
power supply wiring. Always check
the connections, the load and
supply circuit if the motor doesn't
run well. Check minimum gauge for
the length of cord you are using on
the chart below.
GUIDELINES FOR EXTENSION
CORDS
Use a proper extension cord. Make
sure your extension cord is in good
condition. When using an extension
cord, be sure to use one heavy enough
to carry the current your product will
draw. An undersized cord will cause a
drop in line voltage, resulting in loss
of power and cause overheating. The
table below shows the correct size
to use depending on cord length and
nameplate ampere rating. If in doubt,
use the next heavier gauge. The
smaller the gauge number, the heavier
the cord.
Be sure your extension cord is
properly wired and in good condition.
Always replace a damaged extension
cord or have it repaired by a qualified
person before using it. Protect your
extension cords from sharp objects,
excessive heat and damp or wet areas.
Use a separate electrical circuit
for your tools. This circuit must not
be less than a #12 wire with a 10 A
time-lag fuse or a #18 wire with a 6 A
time-lag fuse. NOTE: When using
an extension cord on a circuit with
a #18 wire, the extension cord must
not exceed 25 feet in length. Before
connecting the tool to the power line,
make sure the switch is in the OFF
position and the electric current is
rated the same as the current stamped
on the motor nameplate, running at a
lower voltage will damage the motor.
MINIMUM GAUGE FOR EXTENSION CORDS (AWG)
(When usng 120 volts only)
Ampere Rating
More Than Not More Than 25ft. 50ft. 100ft. 150ft.
0
6
6
10
10
12
12
16
CAUTION
In all cases make certain the
receptacle in question is properly
grounded. If you are not sure,
have a certified electrician check
the receptacle.
11
Total length of Cord
18
16
16
14
18
16
14
12
16
16
14
12
14
12
Not Recommended