Connecting To Power Supply - Stihl MSE 220 C Instruction Manual

Table of Contents

Advertisement

English
Disengage the chain brake.
Pull the hand guard back toward the
N
front handle.
The chain brake is also activated by the
inertia of the front hand guard if the
kickback force of the saw is high
enough: The hand guard is accelerated
toward the bar nose – even if your left
hand is not behind the hand guard, e.g.
during a horizontal cut.
The chain brake will operate only if the
hand guard has not been modified in any
way.
Checking operation of the chain brake
Before starting work:
18
Disengage the chain brake.
N
Switch on the motor.
N
Push the hand guard towards the
N
bar nose.
The chain brake is working properly if
the saw chain comes to a standstill
within a few fractions of a second.
The hand guard must be free from dirt
and move freely.
Chain brake maintenance
The chain brake is subject to normal
wear. It is necessary to have it serviced
and maintained regularly by trained
personnel. STIHL recommends that you
have servicing and repair work carried
out exclusively by an authorized STIHL
servicing dealer. Maintain the following
servicing intervals:
Full-time usage:
every 3 months
Part-time usage:
every 6 months
Occasional usage:
every 12
months

Connecting to Power Supply

The voltage and frequency of the
machine (see rating plate) must match
the voltage and frequency of the power
connection.
The minimum fuse protection of the
power connection must comply with the
specifications – see "Specifications".
The machine must be connected to the
power supply via an earth-leakage
circuit breaker to disconnect the power
supply if the differential current to earth
exceeds 30 mA.
The power connection must correspond
to IEC 60364 and relevant national
regulations.
Depending on the supply voltage and
cord length, the minimum conductor
cross section of the extension cord must
be as follows:
Cord length
Minimum cross
section
220 V – 240 V:
up to 20 m
1.5 mm
20 m to 50 m
2.5 mm
100 V – 127 V:
up to 10 m
AWG 14 / 2.0 mm
10 m to 30 m
AWG 12 / 3.5 mm
Connecting to Wall Outlet
Connect the power tool's plug or the
N
extension cord's plug to a properly
installed wall outlet.
2
2
2
2
MSE 220 C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents