Kenwood TK-8360 Service Manual page 36

Hide thumbs Also See for TK-8360:
Table of Contents

Advertisement

TK-8360/8360H/8360H
Item
Condition
5. DQT
1) TEST CH: Low, Low', Center,
Balance
High', High (5 points)
(Narrow)
2) Deviation meter fi lter
LPF: 3kHz
HPF: OFF
3) Transmit
6. Maximum
1) TEST CH: Low, Low', Center,
Deviation
High', High (5 points)
(Narrow)
2) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
3) Transmit
7. MIC
1) TEST CH: Center
Sensitivity
2) Deviation meter fi lter
Check
LPF: 15kHz
HPF: OFF
3) Transmit
8. DQT
1) TEST CH: Center
Deviation
2) Deviation meter fi lter
(Narrow)
LPF: 3kHz
HPF: OFF
AG: 11kHz/5mV
3) Transmit
9. QT
1) TEST CH: Center
Deviation
2) Deviation meter fi lter
(Narrow)
LPF: 3kHz
HPF: OFF
3) Transmit
10. DTMF
1) TEST CH: Center
Deviation
2) Deviation meter fi lter
(Narrow)
LPF: 15kHz
HPF: OFF
3) Transmit
11. MSK
1) TEST CH: Center
Deviation
2) Deviation meter fi lter
(Narrow)
LPF: 15kHz
HPF: OFF
3) Transmit
Receiver Section
Item
Condition
1. Sensitivity
1) TEST CH: Low, Low', Center,
(Semiauto-
High', High (5 points)
matic)
2) SSG output: –90dBm (7.08µV)
Mod: 1kHz
Dev: ±1.5kHz
36
TENTATIVE
U
(
)
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Deviation
ANT
meter
Deviation
ANT
meter
Oscillo-
scope
AG
AF VTVM
ANT
MIC
ANT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
ANT
Oscillo-
Ext.SP
scope
AF VTVM
Distortion
meter
Adjustment
Parts
Method
FPU
The Deviation of
±0.4dB
20Hz frequency
is fi xed. (FL=30,
FLC=35, FC=40,
FCH=45, FH=50)
Change the 1kHz
adjustment value to
become the same
deviation of 20Hz
within the specifi ed
range.
2.2kHz
±0.05kHz
(According to the
large +, –)
Note:
FPU auto input 1kHz/50mV
Check
1.1kHz~1.8kHz
FPU
0.35kHz
±0.05kHz
0.35kHz
±0.05kHz
1.5kHz
±0.05kHz
1.5kHz
±0.05kHz
Adjustment
Parts
Method
FPU
Auto tuning
Specifi cations / Remarks
Specifi cations / Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-8360hTk-8360hu

Table of Contents