SPECIFICATION
Transmitter frequency
Transmitter radiated power
Transmitter power density
Mounting height
Standard
High
Tilt angles
Detection area
(mounting height = 2.2m)
Detection mode
Minimum speed
Supply voltage
Mains frequency
Power consumption
Output relay (free of potential change-over contact)
• Max. contact voltage
• Max. contact current
• Max. switching power
* only in appropriate areas
DESCRIPTION OF
THE SENSOR
INSTALLATION
TIPS
The sensor must be firmly
fastened to prevent from
vibrating.
FOR QUASI-PRESENCE DETECTION OF PERSONS
: microwave and
microprocessor
: 24.175 GHz
: < 20 dBm EIRP
: < 5 mW/cm²
: from 1.8 m to 3 m
: from 3 m to 4 m *
: 0° to 90° vertical
-30° to + 30° lateral
: 1.5m (W) x 2m (D)
: motion, quasi-presence
detection of persons
: 2 cm/s (measured in the
sensor axis)
: 12V to 24V AC ±10%
12V to 24V DC +30% / -10%
: 50 to 60 Hz
: < 2W (VA)
: 42V AC - 60V DC
: 1A (resistive)
: 30W (DC) / 60VA (AC)
INTERNAL VIEW
The sensor must not be
placed directly behind a
panel or any kind of
material.
INDOOR UNIDIRECTIONAL MOTION SENSOR
Hold time
Temperature range
Application
Degree of protection
Norms and conformity
Dimensions
Weight
Material
Color of housing
Length of cable
Manual adjustment
• Sensitivity (by push buttons)
• Orientation of sensing field (mechanically)
Remote control adjustments
• Sensitivity
• Hold time
• X-MTF Sensitivity
• Detection mode
• Immunity
• Mounting height
• Output configuration
• Door control
• Security
Terminal block
Cable openings
Infrared receiver
LED
Push buttons
Lateral antenna position
adjustment
Planar antenna
Vertical antenna position
adjustment
The sensor must not
The sensor must not
have any object likely to
have any fluorescent
move or vibrate in its
lighting in its sensing
sensing field.
field.
EAGLE X X X X - - - - MTF
EAGLE
MTF
EAGLE
EAGLE
MTF
MTF
USER'S GUIDE
: 0.5 s to 9 s (adjustable)
: -20°C to +55°C
: indoor use only
: IP54
: EMC 2004/108/EC
: 120 mm (W) x 80 mm (H) x 50 mm (D)
: 0.215 kg
: ABS
: anthracite gray, aluminum finish
or white
: 2.5 m
:
10 levels
:
from 0.5s to 9s in 10 levels
:
9 levels
:
uni-/bidirectional, MTF, reverse mode
:
low immunity, normal, increased
immunity
:
standard, high
:
active/passive
:
automatic, permanently open/closed
:
1-4 digit access code
HOUSING
(INTERNAL VIEW)
To avoid damage by
electrostatic discharges,
do not touch any
electronic part of the
sensor.
1/8

Advertisement

loading

Summary of Contents for BEA EAGLE X-MTF

  • Page 1 EAGLE EAGLE X X X X - - - - MTF EAGLE EAGLE USER’S GUIDE INDOOR UNIDIRECTIONAL MOTION SENSOR FOR QUASI-PRESENCE DETECTION OF PERSONS Technology : microwave and Hold time : 0.5 s to 9 s (adjustable) TECHNICAL microprocessor Temperature range : -20°C to +55°C SPECIFICATION Transmitter frequency...
  • Page 2 OPENING THE SENSOR From behind, before installation From the front, after installation PREPARATION FOR MOUNTING THE SENSOR • Paste the template. • Insert screws, but do not screw them • Cut one of the cable openings for the fully home. wire.
  • Page 3: Mechanical Configuration

    Note: All the sensing fields correspond to the following adjustments: MECHANICAL • Bidirectional mode (detection mode: 1) CONFIGURATION • X-MTF deactivated • Hold time: 0.5 s DIMENSIONS OF THE SENSING FIELD (WIDTH, DEPTH, UNCOVERED ZONE) ARE DETERMINED BY THE SENSITIVITY SETTING (0 to 9) The sensing fields correspond to the following adjustments: •...
  • Page 4: Insertion Of Batteries

    INSERTION OF BATTERIES FUNCTIONS CONFIGURATION WITH REMOTE • Open the battery compartment at the back of the remote control; CONTROL • Insert two AAA batteries supplied with the remote control as shown on the left; • Close the battery compartment. (10) Not used 0-9 Number keys (1) (11) Not used...
  • Page 5 Note: All parameters or functions listed in the following tables are only accessible if the sensor is in adjustment session. The red LED flashes slowly. During an adjustment session each parameter may be checked or changed at any time in the following way : PARAMETERS OPERATIONS CHECK...
  • Page 6: Led Signal

    During an adjustment session all parameters may be reset to their factory values in the following way : PARAMETERS OPERATIONS FACTORY Press the SETUP key (19), then press the NUMBER key 9. VALUES All the parameters (except the access code) are reset to the factory values. FACTORY VALUES : Factory Values Table Parameter...
  • Page 7 TROUBLE- The sensor will not unlock when access Improper access code being Cut and restore power supply. No access code is SHOOTING code is entered. entered. required to unlock during the first minute after powering. Press on “unlock”, then on “lock” and introduce a new access code.
  • Page 8 The declaration of conformity and other technical documentation are available on our website or can be requested by phone or mail. BEA S.A. - LIEGE Science Park – Allée des Noisetiers 5 – B-4031 Angleur - Tel: +3243616565 – Fax: +3243612858 – info@bea.be - www.bea.be...