Pipe Bundling
See Figure 32 for proper pipe and cable bundling. Note the placement of the piping
along with the necessary insulation material.
1. Be sure to wrap each pipe with proper insulation material.
2. Secure the piping by wrapping vinyl tape around the pipe.
• Use the narrow size tape for wrapping the actual pipe.
3. You can include the drain hose within the bundled piping and wrap all of them
together using the wider vinyl tape as shown in Figure 33.
• The end of the drain hose outlet must be routed above the ground.
Indoor Unit Installed Above Outdoor Unit
1. Refer to Figure 34 while following the procedures below.
2. Tape the piping, drain hose and connecting cable from down to up.
3. Secure the taped piping along the exterior wall using pipe clamps.
4. Create trap above the electrical connections cover, in order to prevent water
from penetrating electrical components and wiring.
Indoor Unit Installed Below Outdoor Unit
1. Refer to Figure 35 while following the procedures below.
2. Tape the piping, drain hose and connection cable from down to up.
3. Secure the taped piping along the exterior wall using pipe clamps.
4. Create trap above the electrical connections cover, in order to prevent water
from entering the room.
Figure 34: IDU Above ODU - Piping and Trap
Indoor Unit Installed ABOVE
Outdoor Unit - Piping/Trap
Seal small openings
around pipings with a
gum type sealant.
Pipe Clamps
to Secure Pipe
Against Wall
Trap is required to prevent water
from entering into electrical parts.
REFRIGERANT PIPING CONNECTIONS
Connecting cable
Pipings
Taping
Drain hose
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.

Directional Pipe Formation

Figure 32: Cutaway of Proper Pipe and Cable Bundling
Figure 33: Bundling and Taping
Bundling Piping
Drain hose
Figure 35: IDU Below ODU - Piping and Trap
Indoor Unit Installed BELOW
Outdoor Unit - Piping/Trap
Seal a small opening
around the pipings
with gum type sealant.
Trap
Trap
Vapor Line
Insulation Material
Liquid Line
Pipe Sleeve
Insulation
Material
Min. 18 Gauge
Power/Communication
Cable
Pipe
Vinyl tape(narrow)
Wrap with
vinyl tape(wide)
Pipe Clamps
to Secure Pipe
Against Wall