LG LA090HYV Owner's Manual

LG LA090HYV Owner's Manual

Art cool premier wall mounted
Hide thumbs Also See for LA090HYV:

Advertisement

art COOl preMIer wall MOunted
Owner's Manual
Art Cool Premier Wall Mounted
LA090HYV
LA120HYV

Advertisement

Table of Contents
loading

Summary of Contents for LG LA090HYV

  • Page 1 COOl preMIer wall MOunted Owner’s Manual Art Cool Premier Wall Mounted LA090HYV LA120HYV...
  • Page 2 LG Electronics U.S.A., Inc., and are disclosed by LG Electronics U.S.A., Inc., only in confidence. This document is for design purposes only. OL-SZ-ArtCoolPremier-06-14 For continual product development, LG Electronics U.S.A., Inc., reserves the right to change specifications without notice. ©LG Electronics U.S.A., Inc.
  • Page 3: Table Of Contents

    Jet Cool/Heat Operation - Auto Changeover Operation Unit Parts ....................7 Energy Saving Operation Auto Restart Unit Operation ..................9 LG Smart AC Module Remote Controller Remote Controller, Indoor Unit Maintenance ..................19 Indoor Unit - Cleaning Interval Basic Functions ................... 13...
  • Page 4: Safety Instructions

    safety InstruCtIOns Single Zone Art Cool Premier IMpOrtant! • Please read this manual completely before operation of the product. • Follow the instructions in this manual to prevent product malfunction, property damage, injury or death to the user or other people. Incorrect operation due to ignoring any instructions will cause harm or damage. • The level of seriousness is classified by the symbols described below.
  • Page 5 safety InstruCtIOns Single Zone Art Cool Premier Installation safety • Do not install the air conditioner on an unstable surface or where If air enters the refrigerant system, it may result in excessively high there is a danger of it falling; because it may result in death, serious pressure that may lead to personal injury or damage to the equipment.
  • Page 6 safety InstruCtIOns Single Zone Art Cool Premier usage (Continued) with clean water. Failure to do so may result in serious bodily injury. • Do not insert hands or other objects through the air inlet or outlet • Do not let the air conditioner run for a long time when the humidity is while the air conditioner is operating;...
  • Page 7: Unit Parts

    unIt parts Single Zone Art Cool Premier The following table shows the available outdoor and indoor units, their model numbers, along with the factory provided controller. Table 1: Single Zone Art Cool Premier Pairing Table Outdoor Unit Model/Btu/h Indoor Unit Model/Btu/h Controller LAU090HYV / 9,000 LAN090HYV / 9,000...
  • Page 8: Basic Components

    unIt parts Basic Components Indoor unit basic Components Refer to Figure 1 for the basic layout of the components of the Art Cool Premier indoor unit, when following operational, maintenance or troubleshooting instructions in this manual. 3M Micro Protection filter Front panel Smart A/C Slot (optional device) On/Off button...
  • Page 9: Unit Operation

    unIt OperatIOn remote Controller basic remote Control Operation The Single Zone Art Cool Premier comes equipped with a remote controller, enabling convenient air conditioner operation. Table 2 below describes basic button functionality, along with the displayed icon/symbol that will appear on the screen. Figure 3 shows the display screen and placement of the buttons on the remote controller.
  • Page 10 unIt OperatIOn remote Controller Table 2: Remote Controller Operation (Continued) Control Panel Display Screen Description timer buttons (On/Off): Sets the clock timer to enable automatic start and stop times for air conditioner activity. Pressing the enables the user to set the actual time as shown on the display screen.
  • Page 11: Remote Controller

    unIt OperatIOn remote Controller Installing remote Controller batteries Figure 4: Remote Controller Battery Cover 1. Insert AAA batteries (1.5V) before turning on the remote. 2. Remove the battery cover from the back of the unit, by pushing down the tab at the top of the cover ((1) Figure 4). 3.
  • Page 12: Remote Controller, Indoor Unit

    unIt OperatIOn remote Controller, Indoor unit Initializing remote Controller Operation To begin communication between the indoor unit and the remote controller, point the remote controller towards the signal receiver, located at the bottom right hand corner of the indoor unit (see Figure 8). • Make sure to point the remote controller directly at the indoor unit, otherwise the remote might accidentally activate and operate other electronic devices due to the signal being picked up.
  • Page 13: Basic Functions

    basIC funCtIOns Cooling operation - Adjusting the Air Flow (Swing) direction Cooling Operation Heating Operation 1. On the remote controller, press to turn on the power to the 1. On the remote controller, press to turn on the power to the indoor unit.
  • Page 14: Timer Setting Functionality

    basIC funCtIOns timer Setting Functionality setting the timer The Art Cool Premier unit can be programmed through timer settings to turn on and off at set times during the day and night. This functional- ity allows you to save energy and utilize the air conditioner more efficiently. setting the Current time setting sleep Mode The sleep mode is used to turn off the air conditioner at a certain set...
  • Page 15: Advanced Functions

    advanCed funCtIOns Jet Cool/Heat operation - Auto Changeover operation Follow the operational directions in this section to work with advanced functionality and features of the Art Cool Premier Wall Mounted system. auto Operation Jet Cool/Heat Operation (Cooling Only Models) Rapid Cooling and Heating of Room Temperature During this functionality, the fan speed and the temperature adjust This functionality allows you to rapidly cool indoor air (during sum- automatically, based on room temperature.
  • Page 16: Energy Saving Operation

    advanCed funCtIOns Energy Saving operation energy saving Operation - Cooling 2. Press the On/Off button as shown in Figure 12. Placing the unit in this mode minimizes power consumption during cooling. It increases the set temperature to the optimal level for a This function may not be available on all models..
  • Page 17: Auto Restart

    advanCed funCtIOns Auto restart auto restart After a power failure, the unit can be programmed to automatically restart (reboot) and remember its previous settings. This function is a factory default setting. However, should you wish to disable the auto restart feature, follow the steps below. Disable Auto Restart 1.
  • Page 18: Lg Smart Ac Module

    The Smart AC is an optional module with a mobile application which provides monitoring and remote control capabilities from a smart phone. Figure 14 shows the typical configuration of the LG Smart AC Module with a Single Zone Wall Mounted System. See below for Smart AC module system requirements.
  • Page 19: Maintenance

    MaIntenanCe Indoor unit - Cleaning Interval Clean the product regularly to maintain optimal performance and to prevent possible breakdown. Refer to Figure 15 for filter placement. Refer to Table 6 for detailed instructions on maintenance. Review all safety instructions and warnings at the front of this manual; and adhere to all warnings and notes on this page before proceeding with maintenance.
  • Page 20: Cleaning The Air Filter

    MaIntenanCe Cleaning the Air Filter Cleaning 3M Micro Protection Filter 3M Micro protection filter - Cleaning/ • Use two hands when lifting the front panel away from the indoor unit. Maintenance • Maintain a grip on the front panel at all times while removing either Clean the 3M Micro Protection filter located in the indoor unit, once air or 3M Micro Protection Filter.
  • Page 21: Troubleshooting

    If this occurs, refer to Table 6 and Table 8, for initial troubleshooting steps. If the problem persists, contact your local dealer or service center immediately. lG Customer Information Contact LG Customer Information Center immediately if you experience issues listed in Table 7 or Table 8. LG Service Center For USA calls:...
  • Page 22 trOublesHOOtInG Single Zone Art Cool Premier Table 7: Art Cool Premier Troubleshooting Issue Cause Corrective Action There is a burning smell and strange sound coming from the unit. Water leaks from the indoor unit even when the humidity level is low. Immediately turn off the air conditioner.
  • Page 23 trOublesHOOtInG Single Zone Art Cool Premier Table 7: Art Cool Premier Troubleshooting (Continued) Issue Cause Corrective Action • When the heating mode is This is normal operation of the unit. started. During start up, unit is preparing • Vane is almost closed and air warm air.
  • Page 24 The remaining time for the automatic On/Off timer is not shown on App software. Wired remote controllers - PQRCVCL0(QW) or LG Programmable Thermostat - PREMTB10U (only sold in the US). Due to our policy of continuous product innovation, some specifications may change without notification.
  • Page 25 This page intentionally left blank.
  • Page 26 20001747 ISO 9001: 2008 LG ELECTRONICS INC. LG Electronics Commercial Products Support LG Electronics U.S.A., Inc Commercial Air Conditioning Division 1-888-865-3026 USA 11405 Old Roswell Road Follow the prompts for commercial A/C products. Alpharetta, Georgia 30009 www.lghvac.com OL-SZ-ArtCoolPremier-06-14 Supercedes: DFS-OL-AG-001-US_014C07...

This manual is also suitable for:

La120hyvLau090hyvLau120hyvLan090hyvLan120hyv