Menu #3 - Advanced Features - Clifford Matrix 12.5x Installation Manual

Directed electronics
Hide thumbs Also See for Matrix 12.5x:
Table of Contents

Advertisement

2-9 DOUBLE/SINGLE PULSE LOCK: Some vehicles require two pulses on a single wire to lock
the doors. When the double pulse lock feature is turned on, the GREEN/BLACK H2/C wire will
supply two pulses instead of a single pulse. This makes it possible to directly interface with double
pulse vehicles without any extra parts.
2-10 COMFORT CLOSURE: The system can be programmed to close the windows when the
system is armed. A 20-second output starts 200mS after the last lock
Closure output will be canceled if the unlock
wire will provide this function.
NOTE: Comfort Closure is deleted if one-time bypass is activated.
2-11 IMMOBILIZER NORMALLY CLOSED/NORMALLY OPEN: When programmed to the
Normally closed position, the car can be started if power to the alarm is removed for service.
2-12 HOOD TRIGGER NORMALLY CLOSED/NORMALLY OPEN: To program the unit for
either a normally closed or normally open pin switch.
2-13 DUAL SENSOR TRIGGER ON/OFF: When programmed On any two sensors (zones 2, 4, 7)
need to be triggered within 1-second of each other to trigger the alarm/siren. When programmed
Off each sensor will trigger the alarm/siren independently.
NOTE: When On Multi-Level Arming is defeated.
2-14 HIGH SECURITY DISARM ON/OFF: When programmed On the system will silence the
siren on the first press of the unlock button and disarm/unlock on the second press of the unlock
button. When programmed Off (or within 5-seconds of alarm triggering when programmed On)
the system will disarm and unlock on the first press of the unlock button.
2-15 ONE TIME BYPASS ON/OFF: When programmed On the unit will not passively arm for one
cycle when turning the ignition on and off within 3 seconds.

Menu #3 - Advanced Features

3-1 HORN (PULSED)/HORN (CONSTANT): Program for either a pulsed output or a continuous
output when triggered.
3-2 HORN FUNCTION (FULL ALARM ONLY)/SIREN FUNCTION (20mS, 30mS, 40mS,
50mS): Program for output when the alarm is fully triggered or as the siren (arming/disarming and
warnaway and full trigger with timing options).
2006
©
Directed Electronics
button is pressed. If programmed, the lock output
pulse. The Comfort
31

Advertisement

Table of Contents
loading

Table of Contents