Local Codes; Product Features; Pre-Installation Preparation - Desa (V)KC42N series Owner's Operation And Installation Manual

Direct-vent
Table of Contents

Advertisement

Install and use fireplace with care. Follow all
local codes. In the absence to local codes,
use the current National Fuel Gas Code ANSI
Z223.1/NFPA 54* (USA) or the current CSA-
B149.1 Installation Code (Canada).
These are a few facts that can help you under-
stand and enjoy your direct-vent fireplace:
• The venting system may be routed to the
outside of your home in several ways. It
may vent through the roof (vertical) or it
may vent to an outside/exterior wall (hori-
zontal). The vent pipe installation is very
important to allow for proper operation.
You must follow the venting instructions
very carefully for either vertical or horizontal
applications.
• This fireplace may be installed in any room
of your house provided all local codes and
these installation instructions are followed.
• This fireplace requires a wall switch, hand-
held remote or wall thermostat (millivolt) for
operation (see Accessories, page 42).
• This fireplace does not require electricity
to operate.

PRE-INSTALLATION PREPARATION

LOCATION AND SPACE
REqUIREMENTS
Determine the safest and most efficient loca-
tion for your DESA Heating, LLC direct-vent
fireplace. Make sure that rafters and wall
studs are not in the way of the venting system.
Choose a location where the heat output is
not affected by drafts, air conditioning ducts,
windows or doors. Figure 2 shows some com-
mon locations. Be aware of all restrictions and
precautions before deciding the exact location
for your fireplace and termination cap.
When deciding the location of your fireplace,
follow these rules:
• Do not connect this fireplace venting to a
chimney flue serving a separate solid-fuel
burning fireplace or appliance.
• Due to high temperatures, do not locate this
fireplace in high traffic areas, windy or drafty
areas or near furniture or draperies.
• Proper clearances must be maintained.
116239-01K

LOCAL CODES

PRODUCT FEATURES

www.desatech.com
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
• Only the blower requires electricity if in-
stalled and if you plan to install the blower at
a later date, do not forget to wire the outlet at
the bottom of the fireplace when framing.
• A piezo ignitor and ceramic electrode cre-
ate spark to ignite the pilot light. It does not
require any matches, batteries or any other
sources of ignition to light the pilot.
• Each time you turn on your fireplace, you
may notice some amount of condensation
on the inside of the fireplace glass. This
is normal and will disappear after 10-20
minutes of operation.
• Your direct-vent gas fireplace system
(fireplace and venting) is a balanced and
sealed gas operating unit. It requires ap-
proximately 10-20 minutes of operating
time before the flame pattern stabilizes.
• Fireplaces with the suffix of -HA have been
designed to operate at altitudes of 4000
feet and above.
Flush with a wall
Through exterior wall
enclosed in a chase
Figure 2 - Common Fireplace Locations
D
23
/
"
1
4
Figure 3 - Fireplace Bottom Dimensions
Corner
installation
RW
36
/
"
1
4
48"
FW
5