Removing The High Limit Thermostat And The Heater - Whirlpool DryAire LMA1053L Manual

Drying cabinet
Hide thumbs Also See for DryAire LMA1053L:
Table of Contents

Advertisement

REMOVING THE HIGH LIMIT THERMOSTAT AND THE HEATER

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
NOTE: Sharp edges may be present.
1.
Disconnect the power to the drying cabi-
net.
2.
Remove the component panel (see page
4-2 for the procedure).
3.
To remove the high limit thermostat:
a) Disconnect the wires going to the
heater and thermostat terminals.
b) Remove the two Torx screws.
Torx
Screw
(1 of 2)
Thermostat
Wire
High Limit Thermostat
Heater
Wire
4-3
4.
To remove the heater:
a) Remove the two Torx screws from the
high limit thermostat.
b) Disconnect the three wires from the
heater terminals.
Heater
3 Heater Wires
c) Turn the component shelf over and re-
move the four screws from the front and
rear heater brackets.
Heater Bracket Screws
Viewed From Bottom Of Unit