*The plenum should be constructed 1/4---in. (6 mm) smaller in width and depth than the plenum dimensions shown above.
A
FACTORY-SUPPLIED
FIELD-INSTALLED
INSULATION
COMBUSTION- -AIR PIPE FOR NON- -DIRECT VENT (1- -PIPE) APPLICATION
FIELD-SUPPLIED
2-IN. (51 mm) DIA.
PVC 90° ELBOW
COMBUSTION-AIR DISC
(FACTORY-SUPPLIED IN
LOOSE PARTS BAG)
CONCENTRIC VENT FOR DIRECT VENT (2- -PIPE) APPLICATION (ALL MODEL SIZES)
B IN. (MM) DIA PVC
VENT/EXHAUST
1
1/2
(38 mm)
KIT PART NO.
A*
KGAVT0701CVT
33---3/8 (848)
KGAVT0801CVT
38---7/8 (987)
*Dimension A will change accordingly as Dimension D is lengthened or shortened.
Dimension D may be lengthened to 60---in. (1524 mm) maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12--- in. (305