Typical Wiring Schematic; Electrical Data - Bryant PLUS 90X 353AAV Product Data

4--way multipoise condensing gas furnace input rates: 40,000 only
Table of Contents

Advertisement

ELECTRICAL DATA

UNIT SIZE
UNIT VOLTS --- HERTZ --- PHASE
MAXIMUM UNIT AMPS
UNIT AMPACITY
MINIMUM WIRE SIZE
MAXIMUM WIRE LENGTH --- FT (M)
MAXIMUM FUSE OR CKT BKR (Amps)**
TRANSFORMER (24v)
EXTERNAL CONTROL
POWER AVAILABLE
AIR CONDITIONING BLOWER RELAY

TYPICAL WIRING SCHEMATIC

FIVE WIRE
THREE-WIRE
HEATING-ONLY
BLOWER DOOR SWITCH
BLK
BLK
WHT
WHT
GND
AUXILIARY
115-V FIELD-
J-BOX
SUPPLIED
DISCONNECT
036040
115---60---1
8
10.8
14
34 (10.3)
15
HEATING
COOLING
NOTE 2
W
C
R
W
C
R
O
N
T
GND
R
G
O
COM
L
NOTE 1
Y/Y2
24-V
TERMINAL
BLOCK
NOTES:
FURNACE
036060
036080
115---60---1
115---60---1
9.4
9.4
12.5
12.5
14
14
29 (8.8)
29 (8.8)
15
15
40va
12va
21va
24v Standard
FIELD 24-V WIRING
FIELD 115-, 208/230-, 460-V WIRING
FACTORY 24-V WIRING
FACTORY 115-V WIRING
THERMOSTAT
G
Y
TERMINALS
CONDENSING
UNIT
TWO
WIRE
1.
Connect Y-terminal in furnace as shown for proper blower operation.
2.
Some thermostats require a "C" terminal connection as shown.
3.
If any of the original wire, as supplied, must be replaced, use
same type or equivalent wire.
19
048080
060100
115---60---1
115---60---1
115---60---1
9.6
12.1
12.8
15.9
14
12
29 (8.8)
36 (10.9)
36 (10.9)
15
20
FIELD-SUPPLIED
DISCONNECT
208/230- OR
460-V
THREE
PHASE
208/230-V
SINGLE
PHASE
GND
060120
12.1
15.9
12
20
A99440