Bryant PLUS 90X 353AAV Product Data

4--way multipoise condensing gas furnace input rates: 40,000 only

Advertisement

353AAV Plus 90x
4- -Way Multipoise Condensing Gas Furnace
Input Rates: 40,000 Only
4- -WAY MULTIPOISE DESIGN ALLOWS
MORE APPLICATIONS
A UNIQUE SEER SOLUTION
The Plus 90x is an exciting addition to your product line. This
high- -efficiency 4- -way multipoise design furnace allows more
applications while the ECM motor and Bryant's control logic
combine to provide a SEER increase of up to 1.5 points.*
Some of Bryant's best- -engineered components contribute to the
efficient performance of this condensing furnace. The Plus 90x
utilizes Power Lightt hot surface ignition (HSI), which ignites
the burners directly. HSI eliminates gas waste that typical
continuous- -pilot designs can bring. Hot surface ignition has
proven to contribute to reliable start- -up and operation of Bryant
furnaces.
Another deluxe feature included with this furnace is Bryant's
trusted Everlastict secondary heat exchanger; a patented
polypropylene laminate that provides exceptional heat transfer
and corrosion resistance. Using the exclusive flow- -through
design, the secondary heat exchanger reduces the pressure drop in
*as compared to the Air---Conditioning, Heating and Refrigeration Institute's standard coil---only rating (A/Cs up to 3.5 tons) when paired with selected Bryant
evaporator coils.
Product Data
the furnace resulting in lower electrical usage. The high
efficiency achieved by superior heat transfer is made only
better—by optimizing the efficient ECM motor speed tap
locations.
A standard media filter cabinet accessory is provided with the
Plus 90x in order to provide an opportunity to enhance indoor air
quality. As with all other Bryant furnaces, this model is designed
to work as a part of the total home comfort system which includes
elements for cooling, air cleaning, humidification, ventilation and
zoning. Boosting the unit's efficiency with the ECM motor and
Bryant's deluxe features show the Plus 90x has been designed
with the homeowner in mind.
PLUS 90X FEATURES & BENEFITS
Everlastic
polypropylene laminate is used on the secondary heat exchanger
and greatly reduces maintenance.
Perfect Light™ Igniter — Bryant's unique Perfect Light™
igniter is not only physically robust but it is also electrically
robust. It is capable of running at line voltage and does not
require complex voltage regulators as do other brands. This
unique feature further enhances the reliability of the Plus 90x gas
furnace and continues Bryant's tradition of technology leadership
and innovation in providing a reliable and durable product.
FanOn™ — Improves comfort all year long by allowing the
homeowner to select different fan speeds during continuous fan
operation to achieve more or less airflow. This is done right at the
A05085
thermostat.
SmartEvap™ — This feature allows your system to reduce
summertime humidity levels by nearly 10% over standard
systems.
Media Filter Cabinet — Enhanced indoor air quality in your
home is made easier with our media filter cabinet—a standard
accessory on all Deluxe furnaces. When installed as a part of your
system, this cabinet allows for easy and convenient addition of a
Bryant high- -efficiency air filter.
Control Center — Microprocessor controls sequencing and
furnace operation. Equipped with a component test feature and
status indicator light to assist in troubleshooting. Microprocessor
controls blower times to start blower after main burners ignite to
eliminate cold air blowing into rooms.
1
— Exclusive Everlastic coating, a patented
TM

Advertisement

Table of Contents
loading

Summary of Contents for Bryant PLUS 90X 353AAV

  • Page 1 Using the exclusive flow- -through design, the secondary heat exchanger reduces the pressure drop in *as compared to the Air---Conditioning, Heating and Refrigeration Institute’s standard coil---only rating (A/Cs up to 3.5 tons) when paired with selected Bryant evaporator coils.
  • Page 2 1 pipe/Non- -Direct vent (except 140 size unit and in manufactured/mobile home installations) or 2 pipe/Direct vent furnace. All direct vent Plus 90x models can be installed in a manufactured (mobile) home when the optional kit is used. This provides added flexibility to meet diverse installation needs.
  • Page 3: Furnace Overview

    Junction box for 115- -v electrical power supply. (right or left side) Vent outlet uses sealed PVC pipe to carry vent gases from the furnace’s combustion system (right or left side). Secondary condensing heat exchanger (inside), wrings out more heat through condensation of gases.
  • Page 4: Physical Data

    PHYSICAL DATA UNIT SIZE 036040 SHIPPING WEIGHT LB. (KG) 175 (47) LIMIT CONTROL HEATING BLOWER CONTROL (Off Delay) BURNERS (Monoport) GAS CONNECTION SIZE GAS VALVE(Redundant) Manufacturer Minimum Inlet Pressure (in. wc) Maximum Inlet Pressure (in. wc) IGNITION DEVICE DIRECT--- DRIVE MOTOR (ECM X--- 13) MOTOR FULL LOAD AMPS RPM (Nominal) --- SPEEDS...
  • Page 5 *Factory---authorized and field---installed. Gas conversion kits are CSA (A.G.A./C.G.A.) recognized Required for installation on combustible floors when no coil box is used, or when any coil box other than a Bryant cased coil is used. *Model HP and 2S thermostat must be field converted to air conditioner operation.
  • Page 6: Furnace Parts

    Bryant cased coil is used. It is CSA (A.G.A./C.G.A.) design certified for use with select Bryant furnaces when installed in downflow applications.
  • Page 7 A08321...
  • Page 8 DOWNFLOW SUBBASE DIMENSIONS - - IN. (MM) FURNACE CASING FURNACE IN DOWNFLOW APPLICATION WIDTH 17-1/2 Furnace with or without Cased Coil Assembly or (445) Coil Box Furnace with or without Cased Coil Assembly or Coil Box (533) 24-1/2 Furnace with or without Cased Coil Assembly or...
  • Page 9: Media Filter Cabinet Dimensions

    CONDENSATE TRAP MEDIA FILTER CABINET " (600 mm) " (594 mm) Furnace Side " (603 mm) Centerline Screw Slots Opening with Flanges Bent Opening Duct Side Media (146 mm) Filter Cabinet 17" (432) 16" (406) 16" (406) 20" (508) 21" (533) 20" (508) 24"...
  • Page 10: Clearance To Combustibles

    CLEARANCE TO COMBUSTIBLES 335122-201 REV. B LIT TOP A08435...
  • Page 11: Performance Data

    An airflow reduction of up to 7% may occur when using the factory---specified 4 5/16---in. (110 mm) wide, high efficiency media filter. For best furnace efficiency when using the 4---5/16---in. (110 mm) wide media filter, adjust the blower speed tap to near the mid---point of the rise range.
  • Page 12 An airflow reduction of up to 7% may occur when using the factory---specified 4 5/16---in. (110 mm) wide, high efficiency media filter. For best furnace efficiency when using the 4 5/16---in. (110 mm) wide media filter, adjust the blower speed tap to near the mid---point of the rise range.
  • Page 13 COMBUSTION- -AIR AND VENT PIPING FOR DIRECT VENT/2- -PIPE (ALL SIZES) AND NON- -DIRECT VENT/1- -PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS DIRECT VENT (2-PIPE) ONLY ALTITUDE UNIT SIZE FT (M) (BTUH) TERMINATION TYPE 2 Pipe or 2-in 40,000 Concentric 2 Pipe or 2-in 60,000 Concentric...
  • Page 14 COMBUSTION- -AIR AND VENT PIPING FOR DIRECT VENT/2- -PIPE (ALL SIZES) AND NON- -DIRECT VENT/1- -PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS (CON’T.) DIRECT VENT (2-PIPE) ONLY ALTITUDE UNIT SIZE (BTUH) FT (M) TERMINATION TYPE 2 Pipe or 2-in 40,000 Concentric 2 Pipe or 2-in 60,000...
  • Page 15 COMBUSTION- -AIR AND VENT PIPING FOR DIRECT VENT/2- -PIPE (ALL SIZES) AND NON- -DIRECT VENT/1- -PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS (CON’T.) DIRECT VENT (2-PIPE) ONLY ALTITUDE UNIT SIZE (BTUH) FT (M) TERMINATION TYPE 2 Pipe or 2-in 40,000 Concentric 2 Pipe or 2-in 60,000...
  • Page 16 COMBUSTION- -AIR AND VENT PIPING FOR DIRECT VENT/2- -PIPE (ALL SIZES) AND NON- -DIRECT VENT/1- -PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS (CON’T.) ALTITUDE UNIT SIZE DIRECT VENT (2-PIPE) ONLY FT (M) (BTUH) TERMINATION TYPE 2 Pipe or 2-in 40,000 Concentric 2 Pipe or 2-in 60,000...
  • Page 17 3. Assume two 45° elbows equal one 90° elbow. Wide radius elbows are desirable and may be required in some cases. 4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
  • Page 18 MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH - - FT (M) WITH AND WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT* WINTER DESIGN FURNACE SIZE TEMPERATURE °F 〈°C) 20 (---7) 0 (---18) ---20 (---29) 20 (---7) 0 (---18) ---20 (---29) 20 (---7)
  • Page 19: Typical Wiring Schematic

    UNIT 24-V WIRE NOTES: Connect Y-terminal in furnace as shown for proper blower operation. Some thermostats require a "C" terminal connection as shown. If any of the original wire, as supplied, must be replaced, use same type or equivalent wire.
  • Page 20: Typical Installations

    COMBUSTION AIR INLET (NON-DIRECT VENT/ 1-PIPE APPLICATION HUMIDIFIER A/C COIL COMBUSTION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) A/C COIL ELECTRONIC AIR CLEANER FRONT OF FURNACE Upflow Application AIRFLOW FRONT OF FURNACE Downflow Application VENT PIPE HUMIDIFIER GAS-FIRED WATER HEATER A05064 VENT...
  • Page 21 TYPICAL INSTALLATIONS (CONTINUED) VENT PIPE ELECTRONIC AIR CLEANER FRONT OF FURNACE FURNACE CONDENSATE DRAIN REFRIGERATION AIRFLOW COMBUSTION - AIR INLET (NON-DIRECT VENT/ 1-PIPE APPLICATION) REFRIGERATION PIPING AIR CONDITIONING COIL COMBUSTION-AIR INLET (NON-DIRECT VENT/1-PIPE APPLICATION) COMBUSTION–AIR PIPE DIRECT VENT/2-PIPE APPLICATION) AIR CONDITIONING...
  • Page 22: Guide Specifications

    E2010 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.