Start-Up, Adjustment, And Safety Check - Carrier 58SP0A Installation, Start-Up, Operating And Service And Maintenance Instructions

Hide thumbs Also See for 58SP0A:
Table of Contents

Advertisement

58SP0A/58SP1A: Installation, Start–Up, Operating and Service and Maintenance Instructions
SEE NOTES: 1,2,4,5,7,8,9 on the page
following these figures
Fig. 38 – Horizontal Left Application - Vent Elbow Right then Up
SEE NOTES: 1,2,4,7,8,9 on the page
following these figures
Fig. 39 – Horizontal Right Application-Vent Elbow Right
SEE NOTES: 1,2,4,5,7,8,9 on the page
following these figures
Fig. 40 – Horizontal Left Application - Vent Elbow Up
SEE NOTES: 1,2,4,5,7,8,9 on the page
following these figures
Fig. 41 – Horizontal Left Application - Vent Elbow Right
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
SEE NOTES: 1,2,4,5,7,8,9 on the page
following these figures
A03214
Fig. 42 – Horizontal Right Application - Vent Elbow Left then Up
Venting Notes for
1. For common vent, vent connector sizing and vent material: United
States-use the NFGC.
2. Immediately increase to 5-in. (102 mm) or 6-in. (152 mm) vent
connector outside furnace casing when 5-in. (127 mm) vent
connector is required, refer to Note 1 above.
3. Side outlet vent for upflow and downflow installations must use
Type B vent immediately after exiting the furnace, except when
factory-approved Downflow Vent Guard Kit is used in the
downflow position. See Product Data Sheet for accessory listing.
4. Type-B vent where required, refer to Note 1 above.
5. A 4-in.(102 mm) single-wall (26 ga. min.) vent must be used inside
furnace casing and when the factory-approved Downflow Vent
A03218
Guard Kit is used external to the furnace. See Product Data Sheet
for accessory listing.
6. Accessory Downflow Vent Guard Kit required in downflow
installations with lower vent configuration. See Product Data Sheet
for accessory listing.
7. Chimney Adapter Kit may be required for exterior masonry
chimney applications. Refer to Chimney Adapter Kit for sizing and
complete application details. See Product Data Sheet for accessory
listing.
8. Secure vent connector to furnace elbow with (2) corrosion-resistant
sheet metal screws, spaced approximately 180° apart.
9. Secure all other single wall vent connector joints with (3) corrosion
resistant screws spaced approximately 120° apart. Secure Type-B
vent
connectors
recommendations.
START-UP, ADJUSTMENT, AND SAFETY
CHECK
A03215
FIRE HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
This furnace is equipped with manual reset limit switches in the gas
control area. The switches open and shut off power to the gas valve, if a
flame rollout or overheating condition occurs in the gas control area.
DO NOT bypass the switches. Correct problem before resetting the
switches.
A03216
24
Fig. 31
-
Fig. 42
per
vent
connector
WARNING
!
A03219
manufacturer's