Selecting The Power Supply Type - Viessmann Vitotron 100 Series Installation And Operating Instructions Manual

Electric instantaneous water boiler for central heating
Table of Contents

Advertisement

Installation sequence

Selecting the power supply type

Rated output
Connection type to
electric system
4, 6, 8 kW
Type VMN3
FN
MA
RT
Type VLN3
MA
RT
12
12, 16, 20, 24 kW
4, 6, 8 kW
Three-phase
Single-phase
A B
Tcyl
Tos
Tr
A B
Tcyl
If the electrical connection type is configured incorrectly,
e.g. using a single-phase installation at 12, 16, 20 and
24 kW, the configuration fault message "Configuration
fault" appears after commissioning the boiler.
Caution
Do not adjust switches 1 or 2! – Keep factory
settings. Adjust switch 3 according to the power
supply type (1 or 3-phase).