Charging Subcooling (Txv Type Expansion Device); Recommended Tube Diameters - Bryant PURON PLUS 598B User Manual

Two-speed puron plus electric air conditioner
Table of Contents

Advertisement

CHARGING SUBCOOLING* (TXV TYPE EXPANSION DEVICE)
CERTIFICATION APPLIES
ONLY WHEN THE
COMPLETE SYSTEM
IS LISTED WITH ARI.
UNIT
SIZE
024
036
048
060
*Charge in high speed only.

RECOMMENDED TUBE DIAMETERS

UNIT
TUBE LENGTH
SIZE
(Ft)
024
036
0 to 50
048
060
NOTE: Maximum long-line tube length of 50 ft liquid and vapor line sets indicated
above must be followed on all applications. Over 50 ft, refer to Application Guide-
line and Service Manual—Air Conditioners and Heat Pumps Using Puron®
Refrigerant.
As an ENERGY STAR
Partner, Bryant Heating and
Cooling has determined that
this product meets the
®
ENERGY STAR
for energy efficiency.
HIGH
14
15
12
16
LIQUID TUBE
VAPOR TUBE
DIAMETER (In.OD)
DIAMETER (In.OD)
3/8
®
guidelines
—3—
5/8
3/4
7/8
1-1/8
REGISTERED QUALITY SYSTEM