3-dimension array block [index2][index1][index0]
Value
00jjjjjjjiiiiiiiB
00lllllllkkkkkkkB
00nnnnnnnmmmmmmmB
00pppppppoooooooB
4-dimension array block [index3][index2][index1][index0]
Value
00jjjjjjjiiiiiiiB
00lllllllkkkkkkkB
00nnnnnnnmmmmmmmB
00pppppppoooooooB
11.3.10
prm : Parameter ID
Format:
LSB
0pppppppB
MSB
0qqqqqqqB
The Parameter ID indicates the parameter type. When transferring parameters (see "V Parameter
List" below) individually, this field is used to identify the parameter being transferred by its parameter
ID.
11.3.11
idx : Data Index Number
Format:
LSB
0iiiiiiiB
MSB
0jjjjjjjB
The data index number indicates the first array number of the array from which transfer starts.
11.3.12
len : Data Length
Format:
LSB
0lllllllB
MSB
0mmmmmmmB
The value of this field specifies the size of the parameter value stored in the data field. Data length
indicates the length of the array being transferred minus 1 when the parameter contains a character
string or other similar array structure.
11.3.13
data : Parameter Data
Single Parameter Data Size Limit Under the Instrument's System Exclusive message format, the
size of a single message cannot exceed 48 bytes in all other cases. The data size and the array size,
however, can cause a packet to exceed 48 bytes when transferring a single parameter array. In this case,
the IPS and IPR message data length and data index number values can be modified to enable division
of a single parameter value into multiple messages so it can be sent that way.
Meaning
0000H
index2
index1
index0
Meaning
index3
index2
index1
index0