American Standard Mainstream 2948LC-RHO.020 Owner's Manual page 8

60 x 32 whirlpools
Hide thumbs Also See for Mainstream 2948LC-RHO.020:
Table of Contents

Advertisement

C
2
INSTALLATION AND FRAMING INSTRUCTIONS
TYPICAL RECESS INSTALLATION
C
E
LEVELING
NOTE:
STRINGERS
FRONT EDGE
OF BATH MUST
BE SUPPORTED BY
STUD WALL OR
ACCESS PANEL MUST BE LOCATED
AMERICAN STANDARD
ON THE SAME SIDE AS THE MOTOR.
APRON KIT
ALLOW OPEN FRAMING ON
PUMP/MOTOR END FOR SERVICE.
ACCESS PANELS NOT REQUIRED
FOR BATH TUBS.
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
(EXCEPT 2948 WHERE APRON IS PRIMARY ACCESS OPENING)
FOR E & D DIMENSIONS SEE TABLE 1 ON PAGE 5.
This bath must be supported along its entire bottom. Use mortar as bedding material (do not use sand or
foam). Apply enough mortar to support the complete bottom of the bath. After the mortar has been poured,
and before it sets, position whirlpool or bath within recess until the rim is leveled against the leveling stringers
(see "Typical Recess Installation") shown above.
The rim of the bath must not support weight. Allow the mortar material to completely harden before
!
applying weight to the rim or bottom of the bath. Any finish material such as tile or wall board must be
self-supporting if it contacts the deck of the bath.
2948LHO/RHO Replace whirlpool and re-shim the integral support feet, shimming the entire length of the
support feet. Secure the shims using construction adhesive, silicone, mortar or equivalent materials. While not
a necessity, the use of a foundation base consisting of cement, mortar, or grout will help provide a solid and
secure installation.
The rim of the bath must not support weight. If foundation base is used, allow the bedding material to
!
completely harden before applying weight to the rim or bottom of the bath. Any finish material such as tile
or wall board must be self-supporting if it contacts the deck of the bath.
SUGGESTED WHIRLPOOL / BATH INSTALLATION METHOD
WOOD
STUDS
WATERPROOF DRYWALL
OR CEMENT BOARD
SECURE THE BATH TO THE STUDS AS SHOWN FOR WOOD OR STEEL STUD CONSTRUCTION.
12
(305 mm)
24
(610 mm)
TYPICAL FLANGE MOUNTING DETAIL
STUD
TILE
ROOFING NAIL
SEALANT
TUB
1 x 3 (25 x 76mm) WOOD
STRINGER FULL LENGTH
LEVELING STRINGER
1 x 4 (not for support)
NOTE: Tile bead kit not included and
must be purchased separately.
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
F
CUTOUT
C
AS DESIRED
MOUNTING
SURFACE
WATERPROOF
SEALANT
ACCESS PANEL MUST BE LOCATED
BATH
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON PUMP/MOTOR
END FOR SERVICE.
ACCESS PANELS NOT REQUIRED
FOR BATH TUBS.
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
FOR G & F DIMENSIONS SEE TABLE 1 ON PAGE 5.
STEEL
STEEL
STUD
STUDS
WATERPROOF DRYWALL
OR CEMENT BOARD
TILE
SEALANT
TUB
1 x 3 (25 x 76mm) WOOD
STRINGER FULL LENGTH
G
CUTOUT
12
(305 mm)
24
(610 mm)
WASHER
4" (102mm)
DRYWALL
SCREW